The values in the table are in m, they have to be decreased for dosing media with higher
density
•
non-degassing and non-abrasive liquid
•
stroke length: 100 %
•
counterpressure: 1.5 to 3 bar
•
inlet line and dosing head filled (continuous operation).
Pump type
Maximum primed suction lift
Maximum viscosity
[m]
[mPa s]
DMX 4-10
1
400
DMX 7-10x
1
400
DMX 9-10
1
200
DMX 12-10
1
200
DMX 17-4
-1
200
DMX 25-3
-1
200
DMX 7.2-16
1
400
DMX 8-10
1
400
DMX 14-10
1
400
DMX 18-10
1
200
DMX 26-10
-1
200
DMX 39-4
1
100
DMX 60-3
1
100
DMX 13.7-16
1
200
DMX 16-10
1
200
DMX 16-12
1
200
DMX 27-10
1
200
DMX 27-12
1
200
DMX 35-10
1
100
DMX 50-10
1
100
DMX 75-4
-1
100
DMX 115-3
-1
100
*1
Value -1 means 1 m flooded suction
Related information
9.3.5 Sound pressure level
The sound pressure level was tested according to DIN 45635-01-KL3.
Parameter
Value
Sound pressure level
± 55 dB(A)
DMX 221 | |