11.2.5 Technical data of DMX pumps with VFD
General technical data
•
Observe the values stated on the nameplates and in the installation and operating instruc-
tions.
•
For technical data, ambient conditions and operating conditions, see section Technical data.
Electrical data of the VFD
Parameter
Value
Type of current
1 AC (single-phase)
Mains voltage
200-240 V ± 10 %
Mains frequency
47-63 Hz
VFD power
0.25 kW
Motor power
0.18 kW
For electrical data, such as current consumption, see the nameplates of the motor and the VFD.
11.2.5.1 Dimensional sketch of DMX pumps with VFD
For all other dimensions, see section "Dimensional sketch".
Pump type
x
w
y
z
[mm]
[mm]
[mm]
[mm]
all
376
276
128
97
Related information
Subject to alterations.
DMX 221 | |
66