6. Megging
1. Disconnect the power supply.
2. Remove the terminal box. See section
.
3. Measure between terminals T1, T2, T3 and earth. As windings
are star-connected, fault in a winding will show when
measuring all terminals.
4. Replace the entire motor unit in case of fault. See also
measurement of winding resistances in section
5. Fit the terminal box. See section
.
6. Switch on the power supply.
7. Start the pump.
7. Replacing hardware
Fig. 1
Antistatic service kit
7.1 Replacing the terminal box cover
1. Loosen the four screws (251d) and remove terminal box cover
(251b).
2. Clean the sealing faces of terminal box (251a) and the
terminal box cover.
3. Fit the terminal box cover and cross-tighten the screws. Make
sure that the position of the terminal box cover is correct in
relation to the control panel (290).
7.2 Replacing the battery
Applies only to the FM300 functional module.
1. Disconnect the power supply.
2. Remove the terminal box cover. See section
3. Insert a screwdriver under the battery (273b) and prise the
battery out of the isolation cover (277).
Fig. 2
Removing the battery
4. Insert the new battery with the positive pole upwards.
5. Press the battery home with a finger.
6. Fit the terminal box cover. See section
7.3 Fitting the antenna
1. Disconnect the power supply.
2. Remove the terminal box cover. See section
3. Remove the blanking plug (252b) from the terminal box.
4. Fit the union (291) in the terminal box.
5. Lead the antenna into the union from above and tighten the
top part (close to the wire).
6. Click the antenna wire onto the control panel (290). The
antenna wire is long enough to be fitted in both positions of
the control panel.
7. Fit the terminal box cover. See section
An installation with MGE motors must not be megged
as this may damage the built-in electronic parts.
Motor windings may, however, be megged if the
terminal box has been removed.
Never measure between two terminals.
Max. test voltage
Max. leakage current [mA]
1000 VAC/1500 VDC
35
Always use an antistatic service kit when handling
electronic components. This will prevent static
electricity from damaging components.
When unprotected, the component must be placed
on the antistatic cloth.
TM
05 159
0 321
1
The control panel can be turned 180 °.
The old battery must be disposed off according to the
battery directive (2006/66/EC).
T
M
05
70
21
04
13
The new battery must comply with the battery
directive (2006/66/EC).
Make sure that the antenna wire is not sharply bent
or pinched when you fit the terminal box cover.