GRuNDFOS 

Oxiperm batch mOde

QUICK REFERENCE GUIDE

11

10

15

14

13

12

4

3

5

2

1

6

7

8 9

17

18

16

SERVICE

HOLD MIN.

MANU

ALARM

HOLD EXT.

AUTO

NaClO2

HCl

CONTROL AND 

DISPLAY ELEMENTS

LEGEND

item1

 

••••••••••••

 LED - dosing controller for NaClO2 flow 

 

 

LED flashes with correctly set dosing controller

item2

 •••••••••••• LED for NaClO2 tankLED off, level OK

 

 

 

LED flashes with advanced empty alarmLED on, empty alarm

item3

 •••••••••••• LED for bypass water

 

 

 

LED on, bypass water OK

 

 

 

LED flashes if bypass water outside tolerance

item4

 •••••••••••• LED - dosing controller for HCl flow

 

 

 

LED flashes with correctly set dosing controller

item5

 •••••••••••• LED for HCl tank

 

 

 

LED off, level OK

 

 

 

LED flashes, advanced empty alarm

 

 

 

LED on, empty alarm

item6

 •••••••••••• Arrow keys for moving in the display menus

item7

 •••••••••••• Function keys F1, F2 and F3Selection possibility for  

 

 

 

 

individual menu itemsFunction key F4 - reset

item8

 •••••••••••• “Enter” key, confirm inputs

item9

 •••••••••••• Escape key to cancel/switch over to submenu

item10

 •••••••••••Display, 4-line

item11

 ••••••••••• Master switch with EMERGENCY STOP function

item12

 ••••••••••• LED for alarms

 

 

 

LED on or flashing with alarm present 

item13 

••••••••••• Display of automatic or manual mode

 

  LED 

flashes:manual 

control 

    

 

 

LED on:automatic control 

item14 

••••••••••• LED for remote on/off mode

 

 

 

LED flashes: remote on/off by MIN contact for main water    

 

 

LED on:remote on/off by external contact

 

item15 

••••••••••• LED for servicing

 

 

 

LED flashes: system in service menu 

item16 

••••••••••• LED for alarms on the displayLED on or flashing with    

  alarm 

present 

item17 

••••••••••• Connection of display to PLC

 

 

 

LED on, connection OK

 

item18 

••••••••••• LED for display

 

 

 

LED on, display in operation

DISPLAY MENU

Main Menu

Type 1, 2, etc.

Batch mode

Current input

Contact input

Manual control

Target value 

external

Auto Mode

System  

Selection

System type

Operating  

mode

measurement 

units

Manual Mode

Setup

language

Date/time

Program  

version

Min. contact 

water

Exhaust  

enclosure

Bypass  

min-time

Current output

Bus options

Auto start

Code function

Reset function

Logbook

Service mode

Venting

Startup mode

Test mode

L-DIS-SL-01.04-13.indd   3

4/11/2013   2:24:14 PM

Summary of Contents for Oxiperm 164 D

Page 1: ...noid valve 11 Flow meter 12 Precursor check valves 13 Reaction chamber 14 Ball check valve 15 Back pressure valve HCl NaClO2 ClO2 9 3 6 1 8 5 4 7 2 P A P A 14 13 12 11 10 2 3 15 ClO2 preparation capacity pmax bar Consumption of components l h Consumption of bypass water l h input pressure pmax Weight Type continuous operation batch operation 0 5 2 g l 2 3 3 g l kg g h 50 Hz 60 Hz HCl NaClO2 30 10 ...

Page 2: ...e Bypass lIne Venting the HC1O2 Venting the NaC1O2 Venting the H2O Pump Main Menu Main Menu Main Menu Main Menu Service Mode F3 Service Mode F3 Service Mode F3 Service Mode F3 Venting F1 Venting F1 Venting F1 Venting F1 Bypass Line F1 HC1 Pump F2 NaC1O2 Pump F3 H2O Pump F1 SYSTEM INFORMATION CHECKING STATUS DISPLAYING INFORMATION Main Menu Main Menu Logbook F3 Active alarms F2 SYSTEM CHOICE Main M...

Page 3: ...ey to cancel switch over to submenu Item10 Display 4 line Item11 Master switch with EMERGENCY STOP function Item12 LED for alarms LED on or flashing with alarm present Item13 Display of automatic or manual mode LED flashes manual control LED on automatic control Item14 LED for remote on off mode LED flashes remote on off by MIN contact for main water LED on remote on off by external contact Item15...

Page 4: ...0 112 109 111 NaCl O 2 32 34 36 31 33 35 38 40 42 37 39 41 out L N PE WIRING DIAGRAM Power Supply Analog Signal Floating Outputs Inputs L N PE Common point Shield 8V 59 brown 12V 43 NC contact IN OUT GND 60 GND NO contact IN OUT IN 61 blue Dosing controller NaCIO2 IN 44 Batch tank CIO2 overflow 1 2 3 Power supply input 4 5 6 Power supply output 10 11 12 HCI dosing pump 13 14 15 NaCIO2 dosing pump ...

Reviews: