Optional: IP66 (IEC 34-5).
8.5.3 Insulation class
F (IEC 85).
8.5.4 Standby power consumption
5-10 W.
8.5.5 Cable entry sizes
Number and size of cable entries
Motor [kW]
1450-2200 min
-1
2900-4000 min
-1
4000-5900 min
-1
0.25 - 1.5
4 x M20
4 x M20
4 x M20
2.2
1 x M25 + 4 x M20
4 x M20
4 x M20
3.0 - 4.0
1 x M25 + 4 x M20
1 x M25 + 4 x M20
1 x M25 + 4 x M20
5.5
1 x M32 + 5 x M20
1 x M25 + 4 x M20
1 x M25 + 4 x M20
7.5 - 11
1 x M32 + 5 x M20
1 x M32 + 5 x M20
1 x M32 + 5 x M20
Related information
8.5.6 Torques for terminals
Terminal
Thread size
Maximum torque [Nm]
L1, L2, L3, L, N
M4
2.35
NC, C1, C2, NO
M2.5
0.5
1-26, A, Y, B
M2
0.5
8.5.7 Sound pressure level
Motor
[kW]
Rated maximum
speed
[min
-1
]
Speed [min
-1
]
Sound pressure level
ISO 3743
[dB(A)]
1 x 200-240 V
3 x 200-240 V
3 x 380-500 V
0.25 - 0.75
2000
1500
37
-
37
2000
43
-
43
4000
3000
50
-
50
4000
60
-
60
5900
4000
58
-
58
5900
68
-
68
1.1
2000
1500
-
-
37
2000
-
-
43
4000
3000
50
50
50
4000
60
57
60
5900
4000
58
-
58
5900
68
-
68
1.5
2000
1500
-
-
42
2000
-
-
47
4000
3000
57
50
57
4000
64
57
64
5900
4000
58
-
58
5900
68
-
68
69
English (GB)
Summary of Contents for RADIOMODULE 2G4