3.2.4 Pipe connection
Fit the outlet pipe or hose in the Rp 1 1/4 outlet. Steel pipes can be
screwed directly into the pump outlet.
In a permanent installation, fit a union to the outlet pipe to facilitate
mounting and removal. If a hose is used, fit a hose union.
In a permanent installation with a level switch, fit a non-return valve
to the outlet pipe or hose.
3.2.5 Start and stop levels
UNILIFT KP-A
For pumps supplied with a float switch, the difference in level
between start and stop can be adjusted by changing the free cable
length between the float switch and the pump handle.
•
An increased free cable length will result in fewer starts and
stops and a large difference in level.
•
A reduced free cable length will result in more frequent starts
and stops and a small difference in level.
The stop level must be above the pump inlet to prevent the pump
from taking in air.
‹‹‹‹‹‹‹‹‹‹‹‹‹
‹‹‹‹‹‹‹‹ ‹‹‹‹‹‹
‹‹‹‹‹‹‹‹‹‹‹
‹‹‹‹‹‹‹ ‹‹‹‹‹
‹‹‹‹‹‹‹‹‹‹‹
‹‹‹‹‹‹ ‹‹‹‹‹
‹‹‹‹‹‹‹‹‹‹‹
‹‹‹‹‹‹ ‹‹‹‹
‹‹‹‹‹‹‹‹‹
‹‹‹‹‹‹ ‹‹‹
‹‹‹‹‹‹‹‹‹
‹‹‹‹‹ ‹‹‹
‹‹‹‹‹‹‹‹‹
‹‹‹‹‹ ‹‹‹
‹‹‹‹‹‹‹
L
1
2
TM034446
Start and stop levels, UNILIFT KP-A
Pos.
Description
1
Start
2
Stop
UNILIFT KP-A start and stop levels
Minimum cable length
(L):
70 mm
Maximum cable length
(L):
150 mm
Pump type
Start
[mm]
Stop
[mm]
Start
[mm]
Stop
[mm]
KP 150 A
KP 250 A
290
140
335
100
KP 350 A
300
150
345
110
UNILIFT KP-AV
The level difference for pumps with a vertical level switch cannot be
adjusted. Start and stop levels appear from fig. Start and stop
levels, UNILIFT KP-AV.
1
2
TM01
1108
Start and stop levels, UNILIFT KP-AV
Pos.
Description
1
Start
2
Stop
Pump type
Vertical level switch
Start
[mm]
Stop
[mm]
UNILIFT KP 150 AV
UNILIFT KP 250 AV
180
100
UNILIFT KP 350 AV
190
110
8
English (GB)
Summary of Contents for Unilift KP 150
Page 2: ......