3.2.2 Servomotor with analogue control
Fig. 14
Servomotor with analogue control
3.2.3 Manual/automatic remote indication of the position of
the rate valve adjusting spindle
TM
04
09
56
40
09
Item
Description
1
SR, limit switch cam min.
SL, limit switch cam max.
2
Programming buttons
3
Alarm output
4
LEDs
5
DIP switch
6
Mains connection terminals
7
Analogue signal connection terminals
8
Earth terminal
2
3
5
4
6
7
8
1 2
L
R
SET
on
1,
SR
SL
1,
Mains voltage
220-240 V ± 10 %, 50/60 Hz ± 5 %, 100 %
on time (standard)
110-120 V ± 10 %, 50/60 Hz ± 5 %
24 V AC ± 10 %, 50/60 Hz ± 5 %
Rated current
30 mA (at 230 V),
60 mA (at 115 V),
240 mA (at 24 V)
Limit switch -
load capacity
2 A at 250 V
Power consumption Approx. 2 VA
Control variant
Analogue control
Input/Output
Signal input/output
4-20 mA (standard setting)
0-20 mA (switchable)
Setpoint input
4(0) - 20 mA (DC)
Load 250
Overload protection 25 mA
Protection against reverse polarity to -
25 mA
ESD protection, input filter
Resolution: 10 bits
Actual value output
4(0) - 20 mA
Max. load 500
Resolution: 10 bits
Carrying capacity
of signal output
Output current: 4-20 mA
Minimum voltage for
open circuit 10 V
Potentiometer
1000
Actuating time
90 s for 270 ° at 50 Hz
75 s for 270 ° at 60 Hz
Adjustment angle
Max. 270 °
Degree of
protection
IP65
Permitted
ambient
temperature
0 °C to 60 °C
Weight
2.6 kg
Loading capacity of the
Reed contact
Switched power
max. 10 W
Switched current
max. 0.5 A
Switched voltage
max. 200 V (DC)
Carry current
1.0 A
Contact resistance
150 m
Breakdown voltage
min. 250 V (DC)
Degree of protection
IP65
Note
The switch is closed in automatic position!