CDP-S 150
Allgemeiner Teil / General Section
GRUNDIG Service
1 - 3
Technische Daten
Spannungsversorgung
AC Netzadapter .......................................................... DC 3V extern
Batteriebetrieb .......................................... 2 x 1,5V (LR6, UM3, AA)
Ausgangsleistung (DIN 45324, 10% THD)
Ohrhörer ........................................................................... 2 x 15mW
Line Out ........................................................................ 0,6V
±
1,5dB
Anschlüsse
Line Out .................................................................. 3,5mm ø, stereo
DC Buchse .............................................................. 3,5mm ø, (3,0V)
Ohrhörer .................................................................. 3,5mm ø, stereo
CD-Teil
Frequenzübertragungsbereich ..................................... 20Hz - 20kHz
Geräuschspannungsabstand ................................................. > 80dB
Kanaltrennung ........................................................................ > 52dB
D/A-Umsetzung ........................................ 1 bit linear 4 fs digital filter
Technical Data
Power Supply
AC power adapter ...................................................... DC 3V extern
Battery operation ...................................... 2 x 1.5V (LR6, UM3, AA)
Output power (DIN 45324, 10% THD)
Earphone output ............................................................... 2 x 15mW
Line output .................................................................... 0.6V
±
1.5dB
Connections
Line Out .................................................................. 3.5mm ø, stereo
DC connector .......................................................... 3.5mm ø, (3.0V)
Earphones ............................................................... 3.5mm ø, stereo
CD Player
Frequency range .......................................................... 20Hz - 20kHz
S/N ratio, weighted ................................................................. > 80dB
Channel separation ................................................................ > 52dB
D/A conversion ......................................... 1 bit linear 4 fs digital filter
Service Hints
Accumulators
The mains adapter NR 30-6 also works as a charger for Ni-Cd
accumulators with the reference AA IEC (KR 15/51) 1.2V/600mA.
Make sure that the metal cap on the negative pole is stripped more
than 3mm (as illustrated). Otherwise the accumulator will not be
charged!
Laser Unit
When removing the drive mechanism, the flexprint must be provided
with a protective soldered joint before unplugging the flexprint con-
nector to avoid damage to the laser diode by static charges.
When inserting the new drive mechanism the soldered joint
fitted at the factory must be removed after the flexprint is
plugged in.
Flexprint
Servicehinweise
Akkus
Der Netzadapter NR 30-6 dient auch als Ladegerät für Nickel-
Cadmium-Akkus mit der Bezeichnung AA IEC (KR 15/51) 1,2V/
600mA.
Achten Sie darauf, daß das Metallende am Minuspol mindestens
3mm abisoliert ist (wie abgebildet). Ist dies nicht der Fall, wird der
Akku nicht geladen!
Lasereinheit
Beim Ausbau des Laufwerkes muß vor Abziehen der Flexprint-
Steckverbindung eine Schutzlötstelle auf der Flexprintleitung der
Lasereinheit angebracht werden, um eine Zerstörung der Laser-
diode durch statische Aufladung zu vermeiden.
Beim Einbau eines neuen Laufwerkes muß nach Einstecken der
Flexprintleitung die werkseitig angebrachte Schutzlötstelle ent-
fernt werden!
Schutzlötstelle
protective soldered joint
3 mm
min
3mm
min
abisoliert
stripped