6
•
The installation location must
be dry and well ventilated.
Do not place carpets, rugs
or similar covers under
the product. Insufficient
ventilation causes the risk of
fire!
•
Do not cover or block
the ventilation openings.
Otherwise, power
consumption increases
and your product may get
damaged.
•
Product must not be
connected to supply systems
such as solar power supplies.
Otherwise, your product may
get damaged due to sudden
voltage changes!
•
The more refrigerant a
refrigerator contains, the
larger the installation
location must be. If the
installation location is
too small, flammable
refrigerant and air mixture
will accumulate in cases of
refrigerant leakage in cooling
system. The required space
for each 8 gr of refrigerant is
1 m³ minimum. The amount
of refrigerant in your product
is indicated on the Type
Label.
•
Product must not be installed
in places exposed to direct
sunlight and it must be kept
away from heat sources such
as hobs, radiators, etc.
If it is inevitable to install the
product close to a heat source, a
suitable insulation plate must be
used in between and the following
minimum distances must be kept
to the heat source:
- Minimum 30 cm away from
heat sources such as hobs, ovens,
heater units or stoves,
- Minimum 5 cm away from
electric ovens.
•
Protection class of your
product is Type I. Plug the
product in a grounded socket
that conforms the voltage,
current and frequency values
stated on the type label of the
product. The socket must be
equipped with a 10 A – 16 A
circuit breaker. Our company
shall not be liable for any
damages that will arise when
the product is used without
grounding and electrical
connection in accordance
with the local and national
regulations.
•
Product must not be plugged
in during installation.
Otherwise, there is the risk of
electric shock and injury!