16
4.2 Removing the transportation
safety assembly
A
Remove the transportation
safety assembly before
using the dryer for the first
time.
Open the loading door.
There is a nylon bag inside the drum
that contains a piece of styrofoam.
Hold it from its section marked with
XX XX.
Pull the nylon towards yourself and
remove the transportation safety
assembly.
A
Check that no part of
the transportation safety
assembly remains inside the
drum.
4.3 Under counter installation
This product can be installed under a
counter if the height of the counter is
sufficient.
A
While using undercounter
dryer, it should never
be operated without
undercounter installation
part. For the appropriate
undercounter installation
part contact the Authorized
Service.
Dryer Depth
60 cm
54 cm
Stock number
of under-bench
installation part
2979700200 2973600200
Leave at least 3 cm of space around
the sides and the rear wall of the
dryer when installing it under a
counter.
C
If installed under a
countertop, drying
durations can extend.
4.4 Connecting to the drain
In products equipped with condenser
unit, water accumulates in the water
tank during the drying cycle. You
should drain accumulated water
after each drying cycle.
You can directly drain accumulated
water through the water drain hose
supplied with the product instead
of periodically draining the water
collected in the water tank.
Connecting the water drain hose
1-2 Pull hose at the behind of the
dryer by hand in order to disconnect
it from where it is connected. Do not
use any tools to remove the hose.
3 Connect one end of the drain
hose supplied with the dryer to the
connection point from where you
removed the hose of the product in
previous step.
4 Connect the other end of the drain
hose directly to the wastewater drain
or to the washbasin.