Fault in temperature sensor of the
Sensor module.
-
255
Hardware test not valid: Validator
is measuring a coin in the Sensor
module
-
If the code 255 is returned (Code of a non specific fault), it means that is has carried out a
hardware test with a coin in the interior of the Sensor module. It is necessary to carry out
various retries before putting the validator out of order.
When there is the possibility of putting the validator out of order deliberately, it seems
necessary to establish a reset mechanism when the validator responds to a new test without
errors. It is also recommended to try a new test before communicating the fault of the
validator to base.
In the case of various simultaneous errors, the process of the hardware test finalises on
detecting the first error without checking the rest.
The reply to this hardware test is received when the test is completed.
Typical time of reply: 25 ms.
1.2 seconds if the Sensor module is not connected or it does not work correctly.
Command protected by a PIN.
Notes:
a)
A NACK is returned if the Exit module does not have its software correctly loaded.
b)
The reply is one byte, with the exception of error codes 2 and 6 where two bytes are
returned.