E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 39
In Table 8 the error codes that give information on the possible causes of the rejection of
the coin are presented.
Table 8: Command Read Buffered Credit: Error codes
Code
Error
0
Empty event (no error)
1
Coin Rejected (Sensor module is not correctly programmed,
the coin corresponds to a wider acceptance band than the
expected or not valid coin: fraud attempt)
2 Coin
inhibited
5
Timeout error on validation of coin (coin rejected)
6
Timeout in exit detection
8
Error of two passing coins too closely together
13
Sensor module does not work correctly
14
Coin jam in exit detector
20
The String detector has been activated
23
Coin too fast through the exit detector
128 Coin 1 inhibited by the inhibitions register
.. ...
127+
n
Coin ‘n’ Coin 1 inhibited by the inhibitions register
... ...
143 Coin 16 inhibited by the inhibitions register
254 Refund mechanism activated
255 Error code not specified