E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 58
Data 3 = code of state as explained in Table 9:
Table 9: Auto programming state
Code
Error
252
Auto programming cancelled
253
Error in the Auto programming
254
Auto programming in progress
255
Auto programming completed
As the possibility of the machine finishing the Auto programming command does not exist, this
is finalised on introducing 25 coins. On introducing the last coin it will send the message “Auto
programming completed” to the machine.
Command protected by a PIN.
Notes:
a)
A NACK is returned if:
-
The Exit module does not have its software correctly loaded.
-
An error has occurred in programming the data in the Flash memory of the Sensor
module or of the Exit module.
b)
BUSY is returned (6) if the Validator is busy measuring or accepting a coin at the
moment of receiving the command.
c)
This command is not available if the Validator is working in “Secure Mode”.
5.38
CONFIGURATION TO EEPROM [199]
This command is not available if the Validator is programmed in “L66 compatibility” mode.
The Machine requests the Validator to store the configuration data in the non volatile memory
of the Validator: in this case, the Flash memory.
Send:
[Dir] [0] [1] [199] [Chk]
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data