E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 84
5
Incorrect values of the Exit Module configuration data
(user data)
6
Countries id. of the coin programming not compatible
7
The programming data references of the Sensor Module
and Exit Module are not coincident
The data received by the Validator is used by the corresponding programming tools to obtain
the coin programming data files and the firmware data files.
The coin programming data is unique for each Validator. Azkoyen provides files that have the
data of various validators. To find the data to transmit in this file it is necessary to have the
data received with this command such as the serial number of the Validator, see command
REQUEST SERIAL NUMBER [242].
To get the data referring to the new firmware, it is necessary to have the data received using
this command: REQUEST MODULES INFORMATION [96].
Command protected by a PIN.
The maximum time of reply is 1.2 seconds if the Sensor module is disconnected or it does not
work correctly. Typical: 20 ms.
Notes:
a)
The Validator does not answer if it is programmed in “L66 compatibility” mode
5.67
REQUEST COMMS REVISION [ 4 ]
As a reply to this command, the Validator returns the level of implementation of the cctalk
protocol® and the version of the communication software:
Send:
[Dir] [0] [1] [4] [Chk]
Reply:
[1] [3] [Dir] [0] [Data 1] [Data 2] [Data 3] [Chk]
Where: Data 1 = Level of the communication protocol