E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 86
Reply:
[1] [3] [Dir] [0] [Data 1] [Data 2] [Data 3] [Chk] -> ACK with 3 data
Where
Dir = address of the corresponding validator
Data 1 = Rx_timeouts
Data 2 = Rx_bytes_ignored
Data 3 = Rx_bad_checksum
- Rx_timeouts: this counter accumulates the number of times the validator gives a time-
out in the reception of data. If the communication is carried out correctly this value
should be as close to zero as possible
-
Rx_bytes_ignored: if the machine sends the validator very long messages that are
longer than the length of the validator buffer and they are lost, the number of lost bytes
is added to this counter.
-
Rx_bad_cheksum: this counter is incremented each time that a message with an
erroneous checksum is received.
Each time that a reset or power-up is done, the validator counters will start at 0. Before
using and evaluating the data received with this command it is advised to first execute the
command CLEAR COMMS STATUS VARIABLES [3].
The parameters returned by this command give an idea of the noise level in the
communication and how well it is being established.
Command protected by a PIN.
Note:
a) The Validator does not answer if it is programmed in “L66 compatibility” mode