E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 87
5.70
RESET DEVICE [ 1 ]
This command makes the Validator carry out a hardware reset. At the moment of execution
the Validator programme goes into the reset vector. The affected Validator sends an ACK
string immediately before carrying out the reset.
Send:
[Dir] [0] [1] [1] [Chk]
Reply:
[1] [0] [Dir] [0] [Chk] -> ACK without data
All the coin counter information and the configuration of inhibit bits is lost.
Command protected by a PIN.
6.
TELE-PROGRAMMING PROCESS
The coin data stored in the Validator is individualised to account for the manufacturing
tolerances. It has a coin data programming system for programming in the field (tele-
programming) which uses the measurement characteristics (calibration) of each Validator and
that is stored in a data base in the Factory.
To create or modify the programming of a determined Validator the serial number of this
Validator is required. With this number it is possible to obtain the data to transmit to the
Validator. Azkoyen supplies a file that contains the coin data of various validators. The format
of this file is indicated in the specifications.
To create the tele-programming file and find the data corresponding to the Validator installed
in the Machine it is necessary obtain the following information from the Validator:
-
Serial number: use the command REQUEST SERIAL NUMBER [242].
-
Information on the modules that the Validator is made up of: command REQUEST
MODULES INFORMATION [96].
The data to transmit to the Validator consists of a set of strings with the data that should be
transmitted to the validator. The format of this data is as follows: