www.grupotemper.com 5 6 www.grupotemper.com
KPF-02
OPERATING INSTRUCTIONAC CLAMP METER
KPF-02
OPERATING INSTRUCTIONAC CLAMP METER
Specifications
Function
Range & Resolution
Accuracy (% of reading)
DC Current
400.0
μ
A
± (1.8% + 3 digits)
4000
μ
A
AC Current
400.0
μ
A
± (2.0% + 5 digits)
4000
μ
A
4.000 AAC
± (2.5% + 10 digits)
40.00 AAC
400.0 AAC
± (2.0 % + 5 digits)
DC Voltage
400.0 mVDC
± (0.8% + 3 digits)
4.000 VDC
± (1.5% + 3 digits)
40.00 VDC
400.0 VDC
600 VDC
± (2.0% + 3 digits)
AC Voltage
400.0 mVAC
± (0.8% + 10 digits)
4.000 VAC
± (2.0% + 5 digits)
40.00 VAC
400.0 VAC
600 VAC
± (2.0% + 5 digits)
Resistance
400.0
Ω
± (1.0% + 4 digits)
4.000K
Ω
± (1.5% + 2 digits)
40.00K
Ω
400.0K
Ω
4.000M
Ω
± (2.5% + 3 digits)
40.00M
Ω
± (3.5% + 5 digits)
Capacitance 40.00nF
±
(5.0% r 10 digits)
400.0nF
±
(3.0% r 5 digits)
4.000
μ
F
±
(3.5% r 5 digits)
40.00
μ
F
100.0
μ
F
±
(5.0% r 5 digits)
Frequency
5.000Hz
±
(1.5% r 5 digits)
50.00Hz
±
(1.2% r 2 digits)
Sensitivity: 5~5kHz:10Vrms
500.0Hz
5.000kHz min.
5kHz~150kHz:40Vrms min.
@ 20% to 80% duty cycle
50.00kHz
150.0kHz
Duty Cycle
0.5 to 99.0%
±
(1.2% r 2 digits)
Pulse width: 100µs - 100ms, Frequency: 5Hz to 150kHz
Sensitivity: 5~5kHz:10Vrms min.5kHz~150kHz:40Vrms min.
@ 20% to 80% duty cycle
Temp
(type-K)
(probe
accuracy not
included)
-50.0 to
400.0
°
C
-50.0 to -20.
0
°
C
±
7
°
C
-20.0 to
400.0
°
C
±
(3.0% r 3
°
C)
400 to 1300
°
C
400 to
1000
°
C
1000
to1300
°
C
±
(3.0% r 5
°
C)
-58.0 to
400.0
°
F
-50.0 to 0
°
F
±
14
°
F
0 to 400.0
°
F
±
(3.0% r 7
°
F)
400 to 2372
°
F
400 to
1000
°
F
1000
to1300
°
F
±
(3.0% r 10
°
F)
Clamp size Opening 0.9" (23mm) approx
Diode Test Test current of 0.3mA typical; Open circuit
voltage 1.5V DC typical.
Continuity Check Threshold <100
Ω
; Test current < 1mA
Low Battery Indication
“ ” is displayed
Overrange Indication
“OL”” is displayed
Measurements Rate
2 per second, nominal
Input Impedance 7.8M
Ω
(VDC and VAC)
Display
4000 counts LCD
AC Current
50/60Hz (AAC)