WARNINGS FOR THE INSTALLER

1) ATTENTION! To ensure the safety of people, it is 

13) Make sure that a differential switch with threshold of 

important  that  you  read  all  the  following 

0.03 A is fitted upstream of the system.

instructions. Incorrect installation or incorrect use 

14)  Make  sure  that  the  earthing  system  is  perfectly 

of the product could cause serious harm to people.

constructed, and connect metal parts of the means of 

2) Carefully read the instructions before beginning to 

the closure to it.

install the product.

15) The  safety  devices  (EN  12978  standard)  protect 

3) Do not leave packing materials (plastic, polystyrene, 

any  danger  areas  against  mechanical  movement 

etc.)  within  reach  of  children  as  such  materials  are 

Risks, such as crushing, dragging, and shearing.

potential sources of danger.

16) Use of at least one indicator-light is recommended 

4) Store these instructions for future reference.

for every system, as well as a warning sign adequately 
secured to the frame structure, in addition to the safety 

5) This product was designed and built strictly for the 

devices.

use indicated in this documentation. Any other use, not 
expressly indicated here, could compromise the good 

17)  Gruppo  Norton  declines  all  liability  as  concerns 

condition/operation of the product and/or be a source of 

safety and efficient operation of the automated system, 

danger.

if system components not produced by Gruppo Norton 
are used.

6)  Gruppo  Norton  declines  all  liability  caused  by 
improper  use  or  use  other  than  that  for  which  the 

18)  For  maintenance,  strictly  use  original  parts  by 

automated system was intended.

Gruppo Norton.

7)  Do  not  install  the  equipment  in  an  explosive 

19) Do not in any way modify the components of the 

atmosphere: the presence of inflammable gas or fumes 

automated system.

is a serious danger to safety.

20) The installer shall supply all information concerning 

8)  The  mechanical  parts  must  conform  to  the 

manual  operation  of  the  system  in  case  of  an 

provisions of Standards EN 12604 and EN 12605.

emergency,  and  shall  hand  over  to  the  user  the 

For non-EU countries, to obtain an adequate level of 

warnings handbook supplied with the product.

safety,  the  Standards  mentioned  above  must  be 

21)  Do  not  allow  children  or  adults  to  stay  near  the 

observed, in addition to national legal regulations.

product while it is operating.

9)  Gruppo  Norton  is  not  responsible  for  failure  to 

22) Keep radiocontrols or other pulse generators away 

observe  Good  Technique  in  the  construction  of  the 

from children, to prevent the automated system from 

closing  elements  to  be  motorised,  or  for  any 

being activated involuntarily.

deformation that may occur during use.

23)  The  user  must  not  attempt  any  kind  of  repair  or 

10)  The  installation  must  conform  to  Standards  EN 

direct action whatever and contact qualified personnel 

12453 and EN 12445. For non-EU countries, to obtain 

only.

an adequate level of safety, the Standards mentioned 
above must be observed, in addition to national legal 

24)  Transit  is  permitted  only  when  the  automated 

regulations.

system is idle.

11) Before attempting any job on the system, cut out 

25)  Maintenance:  check  at  least  every  6  months  the 

electrical power.

efficiency  of  the  system,  particularly  the  efficiency  of 
the  safety  devices  (including,  where  foreseen,  the 

12) The mains power supply of the automated system 

operator thrust force) and of the release devices.

must  be  fitted  with  an  all-pole  switch  with  contact 
opening  distance  of  3mm  or  greater.  Use  of  a  6A 

26)  Anything  not  expressly  specified  in  these 

thermal  breaker  with  all-pole  circuit  break  is 

instructions is not permitted.

recommended.

GENERAL SAFETY OBLIGATIONS

Summary of Contents for MSC 800

Page 1: ...ileo Galilei s n Zona Ind le 90044 Carini PA vicino DHL tel 39 091 8816371 tel fax 39 091 8816505 e mail automatismi grupponortonsrl 191 it Automatismi per Aperture Manual for installation and mainten...

Page 2: ...here the presence of inflammable gas or fumes automated system is a serious danger to safety 20 The installer shall supply all information concerning 8 The mechanical parts must conform to the manual...

Page 3: ...essary to operate in the work range below the curve Important The curve is obtained at a temperature of 20 C Exposure to the direct sun rays can reduce use frequency down to 20 Calculation of use freq...

Page 4: ...nuts During this operation route the cables through the appropriate openings in the motor body 2 Adjust the height of the gearmotor and the distance from the gate referring to dimensions in Fig 6 Att...

Page 5: ...crew 6x20 mm with relative plate reinforcement 4 Move the gate manually checking if the rack is resting on the pinion and repeat the operations at point 2 5 Position another rack element end to end wi...

Page 6: ...r supply to the system 7 MAINTENANCE Check the functional operation of the system at least every six months especially the efficiency of the safety devices including the operator thrust force and the...

Page 7: ...ogics consult the installation technician The automated systems include obstacle detection and or safety devices photocells edges that prevent the gate from closing when there is an obstacle in the ar...

Page 8: ...lectric box base External cover MSC lock Fold Electric box cover 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 Square cap Bearing 6205 Helical wheel Led tree Unlock Coupling Plug 12 X 47 Bearing 6205 Unlock...