background image

 MONTAGEM/ MOUNTING

ACESSÓRIOS DISPONÍVEIS/ AVAILABLE ACCESSORIES

RB0408

RU2

DINRTT

RTT

LED Vermelho

Estado do Relé (Output2 em
DINRTT e RU2)

Red LED

Relay Status (Output2 in
DINRTT and RU2)

LED Laranja

Menu e Pressão das Teclas

Orange LED

Key press and Menu

- RB0408 - Additional 8 relay board
- RU2 - Additional 2 relay board
- DINRTT - Push button and additional 2 relay board 
- RTT - Push button and additional 1 relay board  

- RB0408 - Placa adicional de 8 relés
- RU2 - Placa de retransmissão adicional 2
- DINRTT - Botão de pressão e 2 placas de relés adicionais
- RTT - Botão de pressão e 1 placa de relés adicional

4.

1.

3.

5.

  3 (M3 x 30mm CSK Philips)

6.

  1 (M3 x 6mm)

2.

Suporte magnético/ Magnet holder

  2 (M3 x 30mm CSK Philips)

Superficie Plana/ Flat surface

5 mm

LED Verde

Estado do Relé(Output1)

Green LED

Relay Status(Output1)

 www.globalsafe.pt 

2

Summary of Contents for CAGS-00017

Page 1: ...e placas E S como RB0408 RTT RU2 DINRTT 0 a 99 seg ou alternancia modo ON OFF IP65 20 C a 50 C sem condensa o Sim via conversor RS485 30 segundos de bloqueio ap s 8 consecutivos C digos PIN inv lidos...

Page 2: ...lay board DINRTT Push button and additional 2 relay board RTT Push button and additional 1 relay board RB0408 Placa adicional de 8 rel s RU2 Placa de retransmiss o adicional 2 DINRTT Bot o de press o...

Page 3: ...NO Bloqueio da Porta El trica Alimenta o DC Electric Door Strike DC powered 12 24 VAC CA Diode ex 1N4001 Orange Blue Yellow Red Black Pink Violet Brown Green White Gray PB GND COM NC C 470 nF R 10K W...

Page 4: ...stances use twisted pair qualified RS485 cable To use the I O board enable it from the CAGS 00017 menu Press 000 B press 5 1 A B to confirm Note The I O board works on 12 VDC whereas CAGS 00017 works...

Page 5: ...1 Relay Remote Unit and request to exit Button RU2 Optional Placa de retransmiss o adicional 2 2 Relay Remote Unit OR rea Segura Secured Area Exterior Outside 12 VDC 1N4007 RU2 Violet Pink COM NO A RS...

Page 6: ...so deleted Resetting the Master Code will also unpair the remote relay unit Dipswitch 1 RESET C DIGO MASTER RESET MASTER CODE 1 2 4 0000 3 5 A 6 B Ex 0000 2578 A B Deligar Alimenta o Disconnect power...

Page 7: ...9 para Rel 9 E OU Pressione 0 para Rel 10 Introduzir 000 Introduzir novo C digo Master 1 a 8 digitos Pressione de 01 a 99 pora tempo em segundos Se pressionar 00 modo de altern ncia Padr o 03 segundos...

Page 8: ...r code 1 to 8 digits Press from 01 to 99 for time in seconds If press 00 toggle mode Default 03 seconds Press from 01 to 99 for time in seconds or press 00 toggle mode Default 03 seconds Press from 01...

Reviews: