7.4.1  Sampler Parts Listing TD (see Figure 7-1) 

 

ITEM 

NO. 

QTY  DESCRIPTION 

MACHINE SIZE  

(CONVEYOR BELT WIDTH) 

 

 

 

18 

24 

30 

36 

42 

29 

GUIDE RAIL 

522200 

522201 

522202 

522203 

522204 

30 

FORWARD BEARING 

522210 

522211 

522212 

522213 

522214 

31 

REAR BEARING 

522220 

522221 

522222 

522223 

522224 

32 

HOLD-DOWN BEARING 

522230 

522231 

522232 

522233 

522234 

33 

HOLD-DOWN BAR 

522240 

522241 

522242 

522243 

522244 

34 

STABILIZER BAR 

522250 

522251 

522252 

522253 

522254 

35 

STABILIZER BEARING 

522260 

522261 

522262 

522263 

522264 

36 

VERT DRIVE GUARD 

522270 

522271 

522272 

522273 

522274 

37 

WEDGE GUARD 

522280 

522281 

522282 

522283 

522284 

38 

HORZ DRIVE GUARD 

522290 

522291 

522292 

522293 

522294 

 

 

 

 

 

 

 

 

ITEM 

NO. 

QTY  DESCRIPTION 

MACHINE SIZE 

(CONVEYOR BELT WIDTH) 

 

 

 

48 

54 

60 

66 

70 

29 

GUIDE RAIL 

522205 

522206 

522207 

522208 

522209 

30 

FORWARD BEARING 

522215 

522216 

522217 

522218 

522219 

31 

REAR BEARING 

522225 

522226 

522227 

522228 

522229 

32 

HOLD-DOWN BEARING 

522235 

522236 

522237 

522238 

522239 

33 

HOLD-DOWN BAR 

522245 

522246 

522247 

522248 

522249 

34 

STABILIZER BAR 

522255 

522256 

522257 

522258 

522259 

35 

STABILIZER BEARING 

522265 

522266 

522267 

522268 

522269 

36 

VERT DRIVE GUARD 

522275 

522276 

522277 

522278 

522279 

37 

WEDGE GUARD 

522285 

522286 

522287 

522288 

522289 

38 

HORZ DRIVE GUARD 

522295 

522296 

522297 

522298 

522299 

Summary of Contents for IS TD

Page 1: ...9575 N 109 th Ave Omaha Nebraska 68142 402 330 1500 www intersystems net SAFETY INSTALLATION OPERATION MAINTENANCE M A N U A L SAMPLER Model TD No PC 522818A Revised 2006 10 26...

Page 2: ...SE RIGHT Pilot Light 10 4 1 5 Digital Display Timer T 1 Standard 10 4 1 6 Main Fuse 11 4 1 7 Index Relay IR 1 11 4 1 8 Reverse Delay Timer Relays 12 4 1 9 Terminal Strip 12 4 2 Sampler Mounted Electri...

Page 3: ...RANTY 22 List Of Illustrations Drawings FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS 4 FIGURE 2 1 TYPICAL INSTALLATION MODEL TD SAMPLING SYSTEM 5 FIGURE 4 1 STANDARD NEMA 12 CONTROL PANEL DETAIL 9 FIG...

Page 4: ...r its operating environment Careless changes could result in death or serious injury to people and reduce the performance and service life of the equipment Never perform any service on this equipment...

Page 5: ...4 FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS...

Page 6: ...based but which could also be volume or quantity based A sample cycle begins when an electric motor drives the slotted sample cutter through the product flow to collect a sample of the material The s...

Page 7: ...of special materials such as stainless steel or nedox coatings D Programmable Controls to sequence the sampler and the sample collection equipment E Abrasion resistant linings of urethane AR carbon s...

Page 8: ...o be sampled as in Figure 2 1 Install the sampler as it is shown and noted on the certified drawings The sampler may or may not be supplied with a partial or a whole conveyor discharge hood Provide ne...

Page 9: ...O NOT locate the controller in a hazardous area D Most applications require that the sampler be in easy view of the controller 3 7 System Wiring Refer to the certified electrical drawing s for specifi...

Page 10: ...BY COMMON SENSE CAN RESULT IN DEATH SERIOUS INJURY AND OR EQUIPMENT DAMAGE LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE 4 1 Control Components And Their Functions FIGURE 4 1 STANDARD NEMA 12 CONTRO...

Page 11: ...ly the timer begins timing down When the illuminated display reads all zeroes 000 the timer has timed out and initiates a sampling cycle The sample pelican traverses through the product flow to collec...

Page 12: ...d the timer is electronically switched to the new units as well 2 LINE FREQUENCY To set the proper line frequency connect the jumper wire to either the 50 HZ or 60 HZ pin These pins are clearly marked...

Page 13: ...mple cutter is in a rest position Upon initiation of a sample cycle the power is routed through the normally closed contacts of the opposite limit sample to the drive motor starter The drive motor sta...

Page 14: ...ed intervals while observing all safety precautions observe the sampler as it operates Inspect for A Loose or missing hardware B Noisy motor or motor reducer bearings C Overheated motor or reducer D A...

Page 15: ...oint where the adjustment of the eye bolts will no longer permit further tightening Shorten the chain by removing a link if necessary 5 4 2 Limit Switch Adjustment Loosen and adjust the limit switch a...

Page 16: ...clutch may need adjustment if it starts to slip When following the instructions below refer to the clutch drawing page 16 A Shutoff and lockout all power electrical pneumatic and hydraulic B Shut dow...

Page 17: ...ng the new facings items 10C sprocket item 12 bushing item 11 H Turn the adjusting nut item 10D clockwise to finger tightness Tighten an additional 1 2 to 3 4 turn I Turn the adjusting nut to position...

Page 18: ...rrect Refer to certified electrical schematic Motor power off Turn on Motor starter heaters tripped Reset Motor burnt out Replace Motor thermal overload tripped Allow motor to cool reset Defective tim...

Page 19: ...lity built piece of machinery As with any machine parts do wear out and fail It is InterSystems recommendation that a small supply of spare parts be kept on hand to cover any minor breakdowns A separa...

Page 20: ...DJ LS LEVER ARM 2 18 35352 LIMIT SWITCH BRKT 2 19 35354 LIMIT SWITCH 2 20 35073 3 ID GUM RUBBER TUBE A R 21 SEE CERT DWG PELICAN DUST SEAL BRACKET 2 22 SEE CERT DWG SAMPLE PELICAN 1 23 SEE CERT DWG CU...

Page 21: ...2 522273 522274 37 1 WEDGE GUARD 522280 522281 522282 522283 522284 38 1 HORZ DRIVE GUARD 522290 522291 522292 522293 522294 ITEM NO QTY DESCRIPTION MACHINE SIZE CONVEYOR BELT WIDTH 48 54 60 66 70 29...

Page 22: ...21 FIGURE 7 1 TD SAMPLER PARTS DRAWING...

Page 23: ...r than by an Authorized Service Representative This warranty does not cover the replacement of parts inoperative because of wear occasioned by use the cost of replacing parts by a person other than an...

Reviews:

Related manuals for IS TD