background image

I.  GENERAL SAFETY INFORMATION 

 

 

SAFETY FIRST! The symbols shown identify 

examples  of  the  safety  labels  and  signs  to 

be found on InterSystems equipment.  They 

are  affixed  to  the  equipment  to  warn  of 

danger  to  persons  and  of  possible 

equipment  damage.    These  signs  must 

never  be  removed,  tampered  with,  painted 

over  or  obscured  in  any way.  (See Page 4 

for label locations.) If labels are damaged or 

become unreadable, replacement labels are 

available from InterSystems.  The user must 

institute  a  continuing  program  to  instruct  all  personnel  in  safe  operating  and  maintenance  procedures,  and  to 

insure that all safety devices, guards, and covers are intact and operable, and that all safety signs are legible. 

 

Consult  InterSystems,  Inc.  before  making  any  changes  to  the  sampler  or  its  operating  environment.    Careless 

changes  could  result  in  death  or  serious  injury  to  people,  and  reduce  the  performance  and  service  life  of  the 

equipment. 

 

Never perform any service on this equipment or any other powered equipment until all power has been shut off 

and  locked  out  so  that  it  cannot  be  restored  without  the  consent  and knowledge of the person who interrupted 

power.  Power includes electrical, fluid, mechanical, or pneumatic energy. 

 

Never perform any service on this equipment without utilizing the required PPE (personal protective equipment).  

Refer to the MSDS(s), material safety data sheet(s), on all the products to which this equipment is in contact with 

to determine what PPE is required. 

 

 

  DANGER  

 

 

THIS EQUIPMENT IS TO BE OPERATED ONLY ON THE VOLTAGE DESIGNATED ON THE 

CERTIFIED ELECTRICAL DRAWING(S)!  FIRE OR EXPLOSION MAY RESULT, WHICH CAN 

CAUSE DEATH, SERIOUS INJURY, AND EXTENSIVE DAMAGE TO EQUIPMENT.  DO NOT 

CONNECT TO VOLTAGES OTHER THAN DESIGNATED. 

 

 

 

 

Summary of Contents for IS TD

Page 1: ...9575 N 109 th Ave Omaha Nebraska 68142 402 330 1500 www intersystems net SAFETY INSTALLATION OPERATION MAINTENANCE M A N U A L SAMPLER Model TD No PC 522818A Revised 2006 10 26...

Page 2: ...SE RIGHT Pilot Light 10 4 1 5 Digital Display Timer T 1 Standard 10 4 1 6 Main Fuse 11 4 1 7 Index Relay IR 1 11 4 1 8 Reverse Delay Timer Relays 12 4 1 9 Terminal Strip 12 4 2 Sampler Mounted Electri...

Page 3: ...RANTY 22 List Of Illustrations Drawings FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS 4 FIGURE 2 1 TYPICAL INSTALLATION MODEL TD SAMPLING SYSTEM 5 FIGURE 4 1 STANDARD NEMA 12 CONTROL PANEL DETAIL 9 FIG...

Page 4: ...r its operating environment Careless changes could result in death or serious injury to people and reduce the performance and service life of the equipment Never perform any service on this equipment...

Page 5: ...4 FIGURE 1 1 TD SAMPLER SAFETY LABEL LOCATIONS...

Page 6: ...based but which could also be volume or quantity based A sample cycle begins when an electric motor drives the slotted sample cutter through the product flow to collect a sample of the material The s...

Page 7: ...of special materials such as stainless steel or nedox coatings D Programmable Controls to sequence the sampler and the sample collection equipment E Abrasion resistant linings of urethane AR carbon s...

Page 8: ...o be sampled as in Figure 2 1 Install the sampler as it is shown and noted on the certified drawings The sampler may or may not be supplied with a partial or a whole conveyor discharge hood Provide ne...

Page 9: ...O NOT locate the controller in a hazardous area D Most applications require that the sampler be in easy view of the controller 3 7 System Wiring Refer to the certified electrical drawing s for specifi...

Page 10: ...BY COMMON SENSE CAN RESULT IN DEATH SERIOUS INJURY AND OR EQUIPMENT DAMAGE LOCKOUT POWER BEFORE PERFORMING ANY MAINTENANCE 4 1 Control Components And Their Functions FIGURE 4 1 STANDARD NEMA 12 CONTRO...

Page 11: ...ly the timer begins timing down When the illuminated display reads all zeroes 000 the timer has timed out and initiates a sampling cycle The sample pelican traverses through the product flow to collec...

Page 12: ...d the timer is electronically switched to the new units as well 2 LINE FREQUENCY To set the proper line frequency connect the jumper wire to either the 50 HZ or 60 HZ pin These pins are clearly marked...

Page 13: ...mple cutter is in a rest position Upon initiation of a sample cycle the power is routed through the normally closed contacts of the opposite limit sample to the drive motor starter The drive motor sta...

Page 14: ...ed intervals while observing all safety precautions observe the sampler as it operates Inspect for A Loose or missing hardware B Noisy motor or motor reducer bearings C Overheated motor or reducer D A...

Page 15: ...oint where the adjustment of the eye bolts will no longer permit further tightening Shorten the chain by removing a link if necessary 5 4 2 Limit Switch Adjustment Loosen and adjust the limit switch a...

Page 16: ...clutch may need adjustment if it starts to slip When following the instructions below refer to the clutch drawing page 16 A Shutoff and lockout all power electrical pneumatic and hydraulic B Shut dow...

Page 17: ...ng the new facings items 10C sprocket item 12 bushing item 11 H Turn the adjusting nut item 10D clockwise to finger tightness Tighten an additional 1 2 to 3 4 turn I Turn the adjusting nut to position...

Page 18: ...rrect Refer to certified electrical schematic Motor power off Turn on Motor starter heaters tripped Reset Motor burnt out Replace Motor thermal overload tripped Allow motor to cool reset Defective tim...

Page 19: ...lity built piece of machinery As with any machine parts do wear out and fail It is InterSystems recommendation that a small supply of spare parts be kept on hand to cover any minor breakdowns A separa...

Page 20: ...DJ LS LEVER ARM 2 18 35352 LIMIT SWITCH BRKT 2 19 35354 LIMIT SWITCH 2 20 35073 3 ID GUM RUBBER TUBE A R 21 SEE CERT DWG PELICAN DUST SEAL BRACKET 2 22 SEE CERT DWG SAMPLE PELICAN 1 23 SEE CERT DWG CU...

Page 21: ...2 522273 522274 37 1 WEDGE GUARD 522280 522281 522282 522283 522284 38 1 HORZ DRIVE GUARD 522290 522291 522292 522293 522294 ITEM NO QTY DESCRIPTION MACHINE SIZE CONVEYOR BELT WIDTH 48 54 60 66 70 29...

Page 22: ...21 FIGURE 7 1 TD SAMPLER PARTS DRAWING...

Page 23: ...r than by an Authorized Service Representative This warranty does not cover the replacement of parts inoperative because of wear occasioned by use the cost of replacing parts by a person other than an...

Reviews:

Related manuals for IS TD