Chapter 2: General Information
Short Sweeps
A shortened sweep is required when using welded sleeve or double frame door with a plenum other than
12 in. The sweep arm is shortened approximately 7 in. from standard length for short sweep.
Figure 2-3
Sweep Details
Table 2-4
Details for 8 in. and 10 in.
Bin
Diameter
# of Inter-
mediate
Wells
Distance from
Center of Bin
to Wall (A)
Distance
between
Center
Well Gate
and First
Intermedi-
ate Well
(B)
Distance
between
Intermediate
Wells (C )
Distance
from Center
of Bin to
Angle Ring
(D)
Distance
between
Center of Bin
to End of
Sweep (E)
30'
2
14' - 11"
4' - 2-1/4"
60"
17' - 5-3/16"
14' - 1/2"
33'
3
16' - 4-15/16"
42"
18' - 11-3/16"
15' - 6-1/2"
36'
3
17' - 10-7/8"
60"
20' - 5-3/16"
17'
42'
4
20' - 10-11/16"
54"
23' - 5-3/16"
19' - 11-1/2"
48'
4
23' - 10-1/2"
62"
26' - 5-3/16"
22' - 11-1/2"
16
PNEG-2108
8" and 10" Standard Duty and IW Standard Duty