DA98D User Manual
11
z
Please install surge absorbing elements in sensible elements (loop) in related
circuits: DC loop is reversely connected in parallel with continuous current diode
while AC loop is connected in parallel with capacitance-resistance absorbing return
circuit.
Attention
U, V and W shall be connected with motor winding in the way of one-to-one correspondence. Reverse
connecting shall be forbidden.
The wires and leads shall be fastened firmly and avoid approaching radiator of the drive unit and the
motor for the fear that the insulation performance will be reduced due to heat.
There will remain large quantities of electrolyzed capacitance in the servo drive unit, so there will a
high remaining voltage even after the power is cut off. Do not touch drive unit or motor within 5
minutes after the power is off!
Summary of Contents for DA98D
Page 1: ...DA98D Digital AC Servo Drive Unit User Manual V5 00 ...
Page 15: ...DA98D User Manual 4 Fig 1 1 Appearance of Servo Drive unit 2 Servo motor appearance ...
Page 16: ...DA98D User Manual 5 Fig 1 2 Servo Motor Appearance ...
Page 23: ...DA98D User Manual 12 Fig 3 1 Standard Wiring for Position Control Mode AM26LS32 Receiver ...
Page 24: ...DA98D User Manual 13 Fig 3 2 Standard Wiring for Speed Control Mode AM26LS32 Receiver ...
Page 71: ...DA98D User Manual 60 Installation Dimension Drawing for BS 120 Model ...
Page 72: ...DA98D User Manual 61 Installment Dimension Drawing for BS 200 Model ...
Page 73: ...DA98D User Manual 62 Installment Dimension Drawing for BS 300 Model ...
Page 74: ...DA98D User Manual 63 Installment Dimension Drawing for BD 80 Model ...
Page 75: ...DA98D User Manual 64 Installment Dimension Drawing for BD 120 Model ...