Operational Parameters
Maximum Charge Current
30 Amps
Input Operating Voltage Range
11.5V to 32V
Maximum Charge Voltage Type A
14.4V
Maximum Charge Voltage Type B
14.6V
Maximum Charge Voltage Type C
14.8V
Solar Panel Power
30W - 300W
Solar Panel V
MP
min / V
OC
max
16V / 32V
Stand by Current
0.03A
Maximum Operating Temperature
70°C
Automatic Derating Above 40°C
1A/°C
Dimensions
162mm x 71.5mm x 32.2mm
Weight
560g
Important Notes:
• Prior to installation, you must determine the suitability of the product to ensure correct application
• Always check with the battery manufacturer for the suitability of this product for your installation
• Where lithium battery banks are involved, check that the BMS system is compatible with this product
• Due to the current required to charge the capacitors in this unit, a spark may occur during connection
• Avoid shorting the output when the unit is operational to prevent damage
• The solar panel minimum votlage is 16
V
MP
and maximum voltage MUST be below 32
V
OC
• Suitable for silicon-based panels such as monocrystalline, polycrystalline and amorphous with 30W –
300W
• Type A (14.4V) generally suits gel & AGM batteries
• Type B (14.6V) generally suits lead and lithium batteries
• Type C (14.8V) generally suits calcium and lead crystal batteries
1. Disconnect the battery supply
2. Choose a mounting position - select a position with good ventilation where air can pass freely around the
unit. Avoid locations such as fuel lines, where external heat is produced or where it may be exposed to
rain. Ensure the unit is installed away from flammable fumes, liquids or materials.
3. Choose an orientation that allows the built-in LED to be visible to confirm operation after installation
4. Connect wires as per our recommended connection sequence above
NOTE:
The external LED indicator can be installed where it will provide a simple visual indication of the
system status
Installation:
Important:
We recommend that the wires are connected in the following sequence:
Ground (BLACK); main battery po (RED); solar panel po (WHITE); chemistry (ORANGE);
ignition (BLUE); output (BROWN) and remote LED (GREEN) (optional).
Warning:
Ensure that you select the correct gauge and heat resistant wiring suitable for where
the unit will be installed
Page 2 of 4
DIBC1224-1230-R3