Wiring The Remote Alarm:
The remote alarm is a normally low 5V digital signal that goes high when the LVD disconnects.
It has a 5mA source/sink capability and can be used to remotely monitor the LVD status.
Wiring With Load Remote Control:
This option enables the remote load connection and disconnection via the load remote control,
yellow wire. When the yellow wire is grounded the load is disconnected otherwise the load is
connected. To configure this mode the green wire must be grounded. This option overrides the LVD
or DDS function but has the same load limitations of 10A continuous or 20A transient.
MPPT12-2P R6
(LED/ Buzzer/PC I/O 5V 5mA)
Blue
Black
LED
BATTERY
WHITE- Panel +
GREY - Non-Critical Load -
BLACK - Battery and Panel -
GREEN - Remote Enable
YELLOW - Load On/Off
RED - B
PVF
BF
OF
NON-CRITICAL