- 49 -
STC 4-16 CT CI
i
nstalling
the
sduC 516
–
The device may only be installed in buildings.
–
The device should only be installed in a room where the permissible
ambient temperature range (-20 °C … +70 °C; PSU max. 50 °C) can be
maintained, even during fluctuations in climatic conditions.
– Mount the device on a non-combustible base.
– Use mounting material suitable for the wall properties.
• If necessary attach four mounting holes at the installation site. The drilling
distances are shown in the drawing below.
• Fasten the unit.
LNB INPUTS
12V DC
LOW
HIGH
T
V
H
V
H
LOW
HIGH
T
V
H
V
H
LNB OUTPUTS
SDUC 516
2 x 16 USER BANDS
OUT 1
16 UB
GSS Grundig Systems GmbH
90471 Nuernberg - Germany
OUT 2
16 UB
95mm
86mm
P
otential
equalisation
(Pe)
Make a potential equalisation (PE) according to IEC/EN/DIN EN 50083 resp.
IEC/EN/DIN EN 60728.
•
Connect the PE connection terminal of the SDUC 516 to a PE rail (sup-
plied by customer) using the PE wire (Cu 4 mm
2
).