Inverting the user signal
For exceptional cases and “older” digital cable receivers, the
spectral position of the user signal can be inverted “
inverse
”.
• Use
▶
◀
/
to position the cursor under “
normal
”.
• Use
to set the spectral position to “
inverse
”.
• Press the
button.
—> The “Testing stuffing” – “
STUFFING
” menu is activat-
ed.
Testing stuffing
The output symbol rate is fixed to a value of 6900 kSymb/s.
If the symbol rate being transmitted exceeds this value
change to a high-order modulation (e.g. from 64 QAM to
256 QAM).
SR=6900
(= “number 1”): Output symbol rate
Bx 4A
SR=6900 (6325)
STUFFING
Number 1 Number 2
(
6325
) (= “number 2”): Current measured output symbol rate.
The value will fluctuate, as the data rates for indi-
vidual stations are dynamically altered by the broad-
casters.
—> The value of “number 2” must not be higher than that
of “number 1”. If the value of “number 2” is higher
than that of “number 1” , question marks “
??
” will
appear in the display.
Bx 4A
SR=6900 (6325)
STUFFING