- 26 -
HDTV 1000 TD
lnb
osCill ator
frequenCy
/
Control
voltage
In this menu set the oscillator frequency of the LNB used and, if necessary, a
LNB control voltage.
Bx 4A
/B
10600 MHz
LNB
off
lnb
osCill ator
frequenCy
• Use
to position the cursor under the digit to be set for the frequency
display.
• Press
to enter the oscillator frequency of the LNB used.
d
i
se
q
C
Comm ands
• In order to set a DiSEqC command, position the cursor under "off" using
button .
• Using buttons
select the desired control voltage.
"abcd" are place-holders for the following setting options:
Bx 4A
10600 MHz
LNB
abcd
Place-holder Value
Description
a
_
No function
T
Sound
D
DiSEqC
b
_
No function
A, B
Sound A or B
0…F
Hexadecimal value for DiSEqC command
0…15
c:
H
Horizontal polarisation
V
Vertical polarisation
d:
h
High-Band
l
Low-Band
Example:
DAHh
means
D
iSEqC (
D
) position
10
(
A
),
H
orizontal (
H
)
h
igh (
h
)
—>
The control voltage only serves to control multiswitches and is not
suitable for power supply of upstreamed components (maximum
load 65mA).