- 9 -
HMM 470 / HMM 470 OIRT / HMS 470
5
Programming
5.1 Preparation
• Connect the test receiver to the HF output on the modulator module.
• Adjust the test receiver to the output channel of the channel strip to be set.
• Switch on the modulator if necessary. For each modulator, there is a green
LED which indicates if the modulator is switched on.
LED – Channel strip “A“
LED – Channel strip “B“
LED – Channel strip “C“
LED – Channel strip “D“
To use the HMM 470 OIRT module the head-end station STC 160 must be set
to OIRT operation mode.
Therefore in the setup menu of the control unit
• press the
button twice.
—> The “Setting the Standard” - “
NORM
” menu is activated.
• Switch to standard “PAL DK” using the
button.
• Press the
button.
—> The “Saving Data” - “
MEMORY
” menu is activated.
• Store the setting using the
button.
—> Always all modulator modules are set.
Mixed operation is not possible!
To operate the
HMM 470 OIRT
module the software version of the control unit
(head-end station) must be “V 8” or higher.