background image

Modifications reserved.

Specification subject to alteration.

Mounting Instructions

Cable connection 

Loosen the screw from the ground
clamp and open the clamp.

Skin the cable as indicated.

All measures in mm, 1:1 scale.

Loosen  the  screws  by  several
turns on both contact plates.

Insert  the  cable  core  laterally
below  the  plastic  pressure  piece.
Retighten  the  screws  to  firmly
press  the  core  onto  the  metal
contacts.

4

3

8

9

17

2

1

Input and output of the socket are
marked  by  corresponding  arrows.

Close  the  ground  clamp  and
retighten the screw.

Insert  the  antenna  socket  into 
the  flush-mount  wall  outlet  box 
(or into the surface-mount frame)
and press the cable into the recess.

Align the socket in the flush-mount
wall outlet box and fix the spreader
clamps  by  turning  in  the  two 
screws.

Screw  down  the  cover  plate.  The
marks must coincide with the cor-
responding outputs of the socket.

8

7

6

5

GSS Grundig Systems GmbH

Beuthener Str. 43  • D-90471 Nürnberg  • http://www.gss.de

82 227 500 02ML

Reviews: