- 21 -
PADA 5100
sid
r ange
—> This menu is only displayed if "fixed" is selected in menu "MUX-
MODE" and the 16 bit SID standard is selected in menu "SID-
NORM".
In this menu an "offset" (range of numbers) can be added to all automatically
assigned SIDs.
Bx 4
0xxx
SID-OFFSET
—> Example: offset
12
SID 101 —> SID
12
101
SID 201 —> SID
12
201
…
—> Adding an offset will avoid to get the same SID twice if several
PADA 5100 are used "in parallel" (and not cascaded).
• Use the
buttons to enter the desired offset.
• Press the
button.
—> The "Output parameters" – "
OUTPUT
" main menu is activated.
o
utPut
Par a meters
In this menu you select whether you whish to output the output transport stream
via the ASI output or the LAN. In addition you can set the output parameters in
the submenus.
Bx 4
ASI
OUTPUT
=>
Bx 4
LAN
OUTPUT
=>
• Use the
buttons to select the desired output ("
ASI
" or "
LAN
").
—> To skip the settings of the output parameters press the
button. The "Input parameters" – "
INPUT
" main menu is activated