- 38 -
PADA 5100
—>
At Cascading the SID-Offset (page 21) of the "upstream" cassettes
must be set to "0xxx"
, so that the static SID assignment of the
"downstream" cassette works.
Table for "static" SID assignment at station filter setting "cascaded"
Input
1
00
2
00
3
00
4
00
5
00
Input SID
SID at the output
101
101
201
301
401
501
102
111
211
311
411
511
103
121
221
321
421
521
104
131
231
331
431
531
105
141
241
341
441
541
106
151
251
351
451
551
201
102
202
302
402
502
202
112
212
312
412
512
203
122
222
322
422
522
204
132
232
332
432
532
205
142
242
342
442
542
206
152
252
352
452
552
301
103
203
303
403
503
302
113
213
313
413
513
303
123
223
323
423
523
304
133
233
333
433
533
305
143
243
343
443
543
306
153
253
353
453
553
401
104
204
304
404
504
402
114
214
314
414
514
403
124
224
324
424
524
404
134
234
334
434
534
405
144
244
344
444
544
406
154
254
354
454
554
501
105
205
305
405
505
502
115
215
315
415
515
503
125
225
325
425
525
504
135
235
335
435
535
505
145
245
345
445
545
506
155
255
355
455
555
If more than one services
are present at one input of
the "upstream" cassettes
(cassettes 1…5 of the exam-
ple), in the "downstream"
cassette (cassette 6 of the
example) the SIDs will be
assigned "statically" accord-
ing to the table beside.
According to this table up
to 6 services per input (cas-
settes 1…5) can be proc-
essed.
Example:
If at input 2 of cassette 2
two services are present,
SID 202 is assigned to the
2nd service at the output of
cassette 2 (according to the
"dynamic" scheme at page
30). This
SID 202
is present at
input 2
of cassette 6.
According to the table be-
side the SID is transformed
in cassette 6 to
SID 212
.
From the 7th service at one
input of the cassettes 1…5
on the SIDs will be trans-
formed "dynamically" in
Cassette 6 (serial SIDs will
be assigned to input SIDs
not included in the table).