- 20 -
PADA 5100
"manual" or "transparent" setting:
—> The "Output parameter" – "
OUTPUT
" menu is activated (page 21).
"fixed" setting:
—> The "SID standard" – "
SID-NORM
" menu is activated.
sid
standard
—> This menu is only displayed if "fixed" is selected in menu "MUX-
MODE".
Herein you can switch over from the common European 16 bit SID standard,
to the common US 8 bit SID standard.
—> Many US devices are not working with the 16 bit version.
The reduction to 8 bit results in a limitation to 255 of the available SIDs
(compared to the 65535 SIDs of the 16 bit version).
—> Then the "SID range" (SID offset) menu is skipped.
Bx 4
16 Bit
SID-Norm
default
• Use the
buttons to select the desired version.
—>
Please note the following if you use the "8 bit setting":
As you can not set a "SID offset", you may either use one cassette or
you have to cascade several cassettes. Therefore all cassettes must
be set to "8 Bit".
• Press the
button.
8 bit setting:
—> The "Output parameter" – "
OUTPUT
" menu is activated (page 21).
16 bit setting:
—> The "SID range" – "
SID-OFFSET
" menu is activated