background image

 

 

- 16 - 

PAMS 4000

 

•  Press the 

 button.

—>  The "Station filter" –  "

INPUT   ASI

" menu is activated.

 

s

tation

 

filter

 

The default setting for the station filter is "

ALL

". In this menu you define the 

stations received to be transmitted. If stations are activated the output symbol 
rate increases.

 

If the station filter is switched off (factory default) all stations of the transport 
stream passes the station filter. As soon as the station filter is activated all sta-
tions are inactive and can be added to the transport stream selectively.

INPUT

OK

ASI

ALL =>

 

•  Use 

 to switch on/off the filter (FILTER/ALL).

 

•  Use   to call up the channel selection.

 

s

tation

 

seleCtion

 

In this menu you select the stations (services) you would like to transmit.

01/10

Box 4   TV      +
Das Erste

—>  All stations from the channel strip will be read, and then displayed 

with name and station type. 

—>  If no station is found, the following error message will appear in the 

display: "

FILTER  no Service

". 

 

In this case, check the ASI input signal.

Summary of Contents for PAMS 4000

Page 1: ...Assembly Instruction PAMS 4000 ...

Page 2: ...ng the cassette 8 3 2 EMC regulations 9 3 3 Cassette overview 10 3 4 Connecting the cassette 10 4 The control panel at a glance 11 4 1 Menu items 11 4 2 Control panel 11 5 Programming 12 5 3 Programming procedure 12 5 2 Notes on level setting 13 5 3 Programming the cassette 13 Selecting the cassette 13 Output parameter level 14 Modulator frequency SAT IF 14 Output symbol rate Spectral position cod...

Page 3: ... No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards EN DINEN50083 2 resp IEC EN DINEN60728 11 must be observed For further information please read the assembly instructions for the head end station used Test the software versions ...

Page 4: ... EU The product fulfils the guidelines and standards for CE labelling page 21 Unless otherwise noted all values are specified as typical ASI input Standard DIN EN 50083 9 Format MPEG ISO IEC 13818 1 Output data rate maximum 72 573 Mbit s dependent on the DVB S IF output parameter settings Level 800 mVPP 10 RF output DVB S IF Frequency range 950 2400 MHz Level range 48 dBμV 95 dBμV Adjustable atten...

Page 5: ...lator Service Filter 47 dB Attenuator ASI IN General The cassette is designed for operation with a PADE 4000 The ASI output signal of the PADE 4000 is fed into the ASI input Individual services can be removed via the program filter Note the maximum possible output data rate of 72 573 Mbits s which depends on the DVB S output parameter settings When the head end station is switched on the two line ...

Page 6: ...equency of the RF output signal of the PAMS 4000 must be set to the frequency of the input crossover GL 100 GL 100 converts the satellite signal vertical and horizontal into a satellite IF band with 950 5450 MHz Vertical input frequency LO 9750 MHz 10700 12750 MHz corre sponds to 950 3000 MHz at output Horizontal input frequency LO 7300 MHz 10700 12750 MHz corre sponds to 3400 5450 MHz at output F...

Page 7: ... 7 PAMS 4000 Sat IF 950 MHz PADE 4000 PAMS 4000 PSU 8 16 optical distribution Feed in switch SOC 100 GL 100 9 5 0 5450 MHz ASI ...

Page 8: ...cassette unplug the power cable from the mains power socket Remove the fastening screws 1 of an unoccupied slot from the bracket of the head end station Insert the cassette in this slot and push it into the housing Align the cassette and apply slight pressure to connect it to the connections of the board Fasten the cassette with the screws 1 Insert the cable termi nal together with the contact was...

Page 9: ...eading in and out for the 19 cabinet are made using cable terminals CLASS KLASSE The attenuation of shielding of the connection lines for ASI and antenna must meet the requirements for Class A Insert the required number of cable terminals in the openings provided in the head end station or in the 19 cabinet Tighten the nuts on the cable terminals until the teeth on the lock washer have penetrated ...

Page 10: ... RS 232 using a PC or notebook and the software BE Flash You can find the current operating soft ware on the website www mygss eu 3 4 Connecting the cassette Connect the ASI output of an PADE 4000 to the ASI input 3 of the PAMS 4000 Connect RF output 2 of the PAMS 4000 via an F feedthrough from the head end station see page 8 Connect the head end station to the mains ...

Page 11: ...e following main menu items Output Output level Output frequency Symbol rate Spectral position code rate FEC Station filter Data rate Factory reset 4 2 Control panel The key pad on the head end station is used to scroll through the menus and menu items one at a time scrolls forward through the menus select parameters in the menus set values initiate actions selects sub menus scrolls backward throu...

Page 12: ...4 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 A B BE Remote please wait V 45 Box 1 t 10 s Ein On M Bedienhinweise blättert Menüs vorwärts blättert Menüs rückwärts wählen die Eingabeposition wählt Untermenü stellen Werte ein speichert alle Eingaben 1 zeigt die Eingabeposition Operating Hints scrolls forward through the menu scrolls backward through the menu select the enter position selects a...

Page 13: ...e menus can be saved by pressing the key You are taken back to the Selecting the cassette menu item Switch on the head end station The display shows the software version e g V 45 The processor reads the cassettes data approximately 10 seconds Ein On BE Remote please wait V 45 t 10 s Selecting the cassette Box 4 V 9 ASI DVBS Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 Box Se...

Page 14: ...ted page 16 Press the button The modulator frequency submenu FREQ is activated Modulator frequency SAT IF In this menu you adjust the output frequency of the modulator FREQ DVB S 950 MHz Using buttons to select the cursor position for the frequency setting Using buttons to adjust the desired frequency 950 MHz 2400 MHz You must add the corresponding LNB oscillator frequency e g 9750 MHz low band 10...

Page 15: ...t of the symbol rate Repeat the procedure by the quantity of the digits to be set Spectral position inverting the user signal For exceptional cases and older digital receivers the spectral position of the user signal can be inverted NEG The default setting is POS Use to place the cursor under POS Use to set the spectral position to NEG Code rate FEC During a transmission data can be lost or change...

Page 16: ...n filter As soon as the station filter is activated all sta tions are inactive and can be added to the transport stream selectively INPUT OK ASI ALL Use to switch on off the filter FILTER ALL Use to call up the channel selection Station selection In this menu you select the stations services you would like to transmit 01 10 Box 4 TV Das Erste All stations from the channel strip will be read and th...

Page 17: ...adio stations the background of the screen of the connected TV or test receiver is darkened The currently selected station is switched off If a service number e g 131 appears instead of TV or RA this indicates that an unnamed station or an undefined data stream is being received Use the buttons to call up the stations in sequential order then use to activate indicated by or to remove them Press th...

Page 18: ...u Station selection is set correctly the current needed data rate is lower than the maximum data rate The value fluctuates since the data rates of individual stations are dynamically modified by the broadcast ers Is the current needed data rate higher than the maximum data rate OVER appears in the display In this case correct the output pa rameter settings pages 15 or the settings of the station s...

Page 19: ...d to the menu item Output parameter level without invoking the factory defaults page 14 Press the button The factory defaults are saved The display shows STORE Back to Selecting the cassette page 13 By pressing the button you will be returned to the menu item Output parameter level without saving the factory defaults page 14 Saving settings Press the button Back to Selecting the cassette page 13 T...

Page 20: ...h current EMC regulations securely Securely tighten the cable connections using an appropriate open ended spanner Measure the output levels of the other cassettes and tune them to a uniform output level using the appropriate level controls or software dependent on the head end station used Please regard the assembly instructions of the respective head end station Mount the front cover see assembly...

Page 21: ...er Straße 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 633 240 0 Fax 49 0 911 633 240 98 www gss de en info gss de Service Phone 49 0 911 633 240 90 service gss de Alterations reserved Technical data E O E by GSS Grundig Systems GmbH V09 001 2019 ...

Reviews: