GK600 User Manual Chapter 6 Specification of Parameters
-
231 -
U0-06 Output power
Range: 0.0%~300.0%
Factory default:
0.0%
U0-07 Master FREQ set source
Range: 0~9
Factory default: 0
U0-08 Auxiliary FREQ set source Range: 0~10
Factory default: 0
U0-09 Master frequency setting
Range: 0.00Hz~600.00Hz
Factory default:
0.00Hz
U0-10 Auxiliary frequency setting Range: 0.00Hz~600.00Hz
Factory default:
0.00Hz
U0-11 Drive status
Range: 0~22
Factory default:
00
Ones place: Running status
0: Accelerating
1: Decelerating
2: Constant speed running
Tens place: drive status
0: Stop
1: Running status
2: Motor parameters are being identified
U0-12 AI1 input voltage
Range: 0.00V~10.00V
Factory default:
0.00V
U0-13 AI2 input voltage
Range: -10.00V~10.00V
Factory default:
0.00V
U0-14 EAI input voltage
Range: 0.00V~10.00V
Factory default:
0.00V
U0-15 AO1 output
Range: 0.0%~100.0%
Factory default:
0.0%
U0-16 EAO output
Range: 0.0%~100.0%
Factory default:
0.0%
U0-17 X6/DI HF pulse frequency Range: 0.0kHz~50.0kHz
Factory default:
0.0kHz
U0-18 Digital input terminal status Range: 00~7F
Factory default:
00
Digital input terminals that correspond to the bits of U0-18 are as shown in Table 6-19: