Parameter
Designation
Scope
Factory
default
Attr
b1-05 Start method
0: From start FREQ
1: DC braking start
2: Flying start 1
3: Flying start 2
0
×
b1-06 Start FREQ
0.00Hz~upper limit FREQ
0.00Hz
×
b1-07 Holding time of start FREQ 0.0s~3600.0s
0.0s
△
b1-08 DC braking current at start 0.0%
~
200.0%
0.0%
△
b1-09 DC braking time at start 0.00s~30.00s
0.00s
△
b1-10 Flying start 1 current
0.0~200.0%
100.0%
×
b1-11 Flying start 1 Decel time 0.1s~20.0s
2.0s
×
b1-12
Flying start 1 adjustment
coeff
0.0
~
100.0%
1.0%
×
b1-13 Stop method
0: Ramp to stop
1: Coast to stop
2: Ramp to stop + DC brake
0
×
b1-14
Start FREQ of DC brake
stop
0.00Hz~upper limit FREQ
0.00Hz
×
b1-15 DC brake current
0.0%~200.0%
0.0%
△
b1-16 DC brake time
0.00s~30.00s
0.00s
△
b1-17 Overexcitation brake
0: Disabled
1: Enabled
1
×
b1-18 Dynamic brake
0: Disabled
1: Enabled
0
×
b1-19
Dynamic brake threshold
voltage
650V~750V
720V
×
b1-20
Auto restart when power up
again after power loss
0: Disabled
1: Enabled
0
×
b1-21
Time delay of auto restart
when power up again
0.0s~10.0s
0.0s
△
Group b2 Accel/Decel Parameters
b2-00
Accel/Decel time resolution
0:0.01s
1:0.1s
2:1s
1
×
b2-01 Accel time 1
0s~600.00s/6000.0s/60000s
6.0s
△
b2-02 Decel time 1
0s~600.00s/6000.0s/60000s
6.0s
△
b2-03 Accel time 2
0s~600.00s/6000.0s/60000s
6.0s
△
b2-04 Decel time 2
0s~600.00s/6000.0s/60000s
6.0s
△
b2-05 Accel time 3
0s~600.00s/6000.0s/60000s
6.0s
△
b2-06 Decel time 3
0s~600.00s/6000.0s/60000s
6.0s
△
b2-07 Accel time 4
0s~600.00s/6000.0s/60000s
6.0s
△