DAILY FUELING & FIRING ROUTINE
Prior to opening the fuel door, pull the damper plate rod out, turn the inducer fan switch off and wait 60 seconds. After the 60 seconds
has passed, open the fuel door slowly and stand behind the door so that the door is between you and the fire box. Allow another 60
seconds to pass before raking the coals, shaking down the ashes, cleaning the heat exchanger and filling the fire box. Failure to wait
may cause an injury from a fire flare back.
Since the inducer blows air into the ash pan area it is critical to remove the ashes daily even though the ash pan area is not full. Check
heat exchanger weekly. Store ashes in a covered metal container until all cinders have thoroughly cooled prior to dispersal.
Do not load the fire box more than thirty percent (30%) with coal. If additional fuel is added you will not maintain a hot enough burn
and your efficiency rate will deteriorate. Only add enough coal to provide heat until the next fueling time. Overfilling the fire box will
cause the fire to smolder, create excessive creosote and result in more fuel being consumed.
SAFETY
Whenever the loading door is to be opened, it should always be cracked slightly to allow oxygen to enter and burn off any combustion
gases that are present before fully opening. Failure to do this could result in sudden ignition of the unburned gases when the door is
opened.
A stove should never be filled with excess coal so that the flue gas exit is blocked or impeded in any way.
STARTING DURING A PROLONGED POWER FAILURE
During a prolonged power failure, where no power is being sent to the furnace, do not load with new fuel or try to start a new fire. It
is recommended that you contact your local dealer or Greentech Manufacturing, Inc. to find out what size of generator is needed to
keep your furnace running. Once an approved generator is connected to the stove, the unit may be started normally.
OPERATION
WARNING!!!
Risk of Fire: Do not operate with fuel loading and/or ash removal doors open. Do not store fuel or
other combustible materials within marked installation clearances. Inspect and clean flues and chimney regularly.
CAUTION!!!
Hot Surfaces: Keep children away. Do not touch during operation.
CAUTION!!!
Do not to start the unit during a prolonged power failure.
25
Summary of Contents for Crown Royal Stoves Multi-Pass 7200MP
Page 2: ......
Page 4: ......
Page 6: ...6 ...
Page 8: ...8 ...
Page 11: ...FURNACE FLOOR PLAN Model 7200MP Model 7300MP 11 ...
Page 12: ...FURNACE FLOOR PLAN Model 7400MP Model 7500MP 12 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 31: ...ELECTRICAL WIRING DIAGRAM 7200MP 7300MP 7400MP 31 ...
Page 32: ...ELECTRICAL WIRING DIAGRAM 7500MP 32 ...
Page 38: ...38 ...
Page 42: ...Model 7500MP 42 ...
Page 51: ...51 ...
Page 52: ...OWNER S MANUAL ...