Usage of authorized Control chemical is required in all Crown Royal Stoves. To uphold your warranty annual water testing is necessary.
Do not allow moisture to come in contact with ashes in firebox or heat exchanger. It is mandatory to have a rain cap on the termination
of your chimney.
Frequently check for accumulated soot, creosote, and ash build-up until experience shows how often cleaning is necessary.
Check daily for creosote build-up until experience shows how often cleaning is necessary. Be aware that the hotter the fire, the less
creosote is deposited, a weekly cleaning may be necessary in warmer weather, while a monthly cleaning may be adequate in the coldest
months. Have a clearly understood plan of how to handle a chimney fire.
See Below (RUNAWAY CHIMNEY FIRE)
Daily Maintenance
•
Check water level and add as necessary.
•
Remove collected ash from the shaker grates and ash pan.
•
Check if temperature setting corresponds to thermometer.
•
Check for ash buildup in firebox and clean as necessary (Use a metal container to empty ashes into.)
Note:
Unit must be shut down in order to fill up and clean the ash pan!
Weekly Maintenance
•
Check air bypass tubes and chimney; remove any creosote, soot or ash build-up that may have occurred. Check for ash build-up
in heat exchangers and clean as necessary.
•
Check fan and solenoid to ensure proper air velocity is happening at ejection points.
Monthly Maintenance
•
Check the water float and add water until excess flows from the overflow pipe located in front of the chimney.
Annually Maintenance
•
Lubricate fan, solenoid shaft and shaker grate.
•
Check fan and solenoid to ensure proper air velocity is happening at ejection points.
•
Check the door gasket and replace if needed.
•
Clean out any ash buildup from back.
•
Check blower motor bushings and oil as needed.
•
Check air bypass tubes and chimney; remove any creosote, soot or ash build-up that may have occurred.
•
At the end of the season, thoroughly clean out all the ashes in the firebox, chimney, ash pan and heat exchanger.
•
Place a chimney cap on the chimney in order to keep rain from entering the firebox.
Remember:
Your preventive maintenance program will give you years of trouble-free service.
Off Season Maintenance
•
At the end of the heating season, shut off the pump, empty the fire box and heat exchanger of all ash, remove the creosote,
clean the damper plate and clean the chimney. Remove and clean the inducer blower, clean the ash pan area, check the door
gaskets and replace as necessary.
•
Drain the system if needed, refill to the top, treat and test the water, turn on the circulation pump for at least four hours to mix
the treatment thoroughly, check for leaks and then shut the pump off.
•
Care for the exterior of your furnace is minimal. The unit may be washed using water and a mild non-abrasive cleaner suitable
for painted surfaces. Avoid direct water pressure to electrical components and connections.
CONTACT YOUR LOCAL DEALER FOR ANY QUESTIONS REGARDING MAINTENANCE.
CAUTION!!!
Make certain that all electrical power to the furnace and components are shut off before washing.
MAINTENANCE
27
Summary of Contents for Crown Royal Stoves Multi-Pass 7200MP
Page 2: ......
Page 4: ......
Page 6: ...6 ...
Page 8: ...8 ...
Page 11: ...FURNACE FLOOR PLAN Model 7200MP Model 7300MP 11 ...
Page 12: ...FURNACE FLOOR PLAN Model 7400MP Model 7500MP 12 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 31: ...ELECTRICAL WIRING DIAGRAM 7200MP 7300MP 7400MP 31 ...
Page 32: ...ELECTRICAL WIRING DIAGRAM 7500MP 32 ...
Page 38: ...38 ...
Page 42: ...Model 7500MP 42 ...
Page 51: ...51 ...
Page 52: ...OWNER S MANUAL ...