If the furnace fails to heat up:
•
Check fire.
•
Check fan for operation.
•
Check that solenoid damper is open to allow air velocity.
•
Check water level of furnace.
•
Check for creosote blockage at chimney and bypass trough.
•
Check temperature setting.
•
Check for power at furnace.
If furnace water is hot, but buildings do not have heat:
•
Check pumps and check for closed valves.
•
Check filter or Y-Strainer for flow blockage.
•
Check for air in system at exchanger by bleeding off.
If furnace boils:
•
Check that door is closing properly and that door gasket is completely sealed.
•
Check that the ash pan door is properly closed, and the gasket is completely sealed.
•
Check that the solenoid damper plate is opening and closing without hang-ups.
•
Check that the flexible air duct is connected to the blower and the bottom elbow of the furnace.
•
Check that the temperature settings are correct and water levels.
If furnace has shut down:
•
Check to ensure that the unit has power (does the outside light work).
•
Check the water temperature (furnace has a high temperature cut-out of 190 degrees F.).
•
If all the checks have not corrected the problem, have a qualified technician check the control panel.
Blower will not come on:
•
Check to see if the high limit switches may be shut off because of water temperature is higher than aqua stat setting.
•
Wait and allow water to cool down. Reset snap disc.
TROUBLESHOOTING
29
Summary of Contents for Crown Royal Stoves Multi-Pass 7200MP
Page 2: ......
Page 4: ......
Page 6: ...6 ...
Page 8: ...8 ...
Page 11: ...FURNACE FLOOR PLAN Model 7200MP Model 7300MP 11 ...
Page 12: ...FURNACE FLOOR PLAN Model 7400MP Model 7500MP 12 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 31: ...ELECTRICAL WIRING DIAGRAM 7200MP 7300MP 7400MP 31 ...
Page 32: ...ELECTRICAL WIRING DIAGRAM 7500MP 32 ...
Page 38: ...38 ...
Page 42: ...Model 7500MP 42 ...
Page 51: ...51 ...
Page 52: ...OWNER S MANUAL ...