www.gtm
-
gmbh.com
Series MKA (eng.) 14/09/2022
Page 17
#
PrecisionWins
Technical Data
7.2 Load range
x
Size
I
II
III
IV
V
VI
Load range
1)
F
xy
kN
0.3 - 30
1 - 80
2 - 200
3 - 300
5 - 500
25 - 500
Load range
1)
F
z
kN
1 - 100
2 - 200
5 - 500
10 - 1000
20 - 1000
100 - 4000
Load range
1)
M
xy
N·m
5 - 1500 25 - 5000 100 - 20000 250 - 25000 1000 - 100000
5000 - 200000
Load range
1)
M
z
N·m
5 - 1000 25 - 5000 100 - 10000 250 - 15000
1000 - 25000
5000 - 200000
1) This specifies the minimum and maximum load of the component for which an M KA can be interpreted. Not every combination is possible.
For the best possible design for your application please contact us. Other special load ranges /designs on request
7.3 Configurations
x
MKA size
I
II
III
IV
V
VI
± F
nom
1)
kN
5
40
100
160
200
500
± M
nom
2)
N·m
250
3000
10000
15000
20000
50000
Rated
characteristic value
C
Fx
, C
Fy
mV/V
1.6
Rated
characteristic value
C
Fz
mV/V
0.4
Rated
characteristic value
C
Mx
, C
My
mV/V
Rated
characteristic value
C
Mz
mV/V
1
2
1
1) Fx ,Fy, Fz
2) M x ,M y, M z
Other combinations of forces and moments are possible. The resulting nominal values are gladly given on request.
2
0.4
2
▶
Other combinations of forces and torques vectors are possible.
The resulting signals are gladly given on request.