18
Step 15
Strip approximately 3/16" of insulation from each wire of
the opener power cable. Twist each exposed wire tightly
(there are seven [7] wires inside the power cable sheath).
Loosen sealing nut on strain relief hub at bottom of
control box. Insert power cable into control box through
strain relief. Thread approximately 6" of the power cable
into the control box and retighten sealing nut until the
power cable locks into place.
Step 16
Insert the stripped power cable wires into the
appropriate terminals on the
OPENER
terminal
block. The green wire should be inserted into the
GRN
terminal, the blue wire into
BLU
, the orange
wire into
ORG
, black wire into
BLK
, and the red
wire into the
RED
terminal, white wire into
WHT
,
and brown wire into
BRN
.
Tighten the set screws against the end of the wires.
A dab of petroleum jelly on each terminal will help
prevent corrosion.
Correct
Wrong
Wrong
Wire
Terminal
Block
Terminal
Block
Terminal
Block
Wire
Wire
Connecting Opener Power Cable
Sealing Nut
Hub
Lock Nut
Strain Relief
Step 14
Make sure the control box power switch is in the
OFF
position.
The ON/OFF Switch is located on the bottom of the control box.
Remove the control box cover and slide the battery into position
with its terminals to the
RIGHT
(
see illustration
). Connect the
BLACK
battery wire to the
NEGATIVE
(
–
) battery terminal.
Connect the
RED
battery wire to the
POSITIVE
(
+
) terminal.
Pay close attention to the color of the wires. If the wires are
connected incorrectly, the control board will be damaged
.
NEVER
insert the battery with the terminals to the left.
RED wire to POSITIVE (
+
) terminal
BLACK wire to NEGATIVE (
–
) terminal
RED
BLACK
Power cable from
operator (master) arm
SWIT
C
H
ST
ALL FORCE
MI
N
MAX
MASTER INPUTS
GRN
WHT
BL
UE
BRN
ORG
RED
BLK
GRN
BLK
RED
RECEIVER
COM
COM
CYCLE
CLOSE
SAFETY
EXIT
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
J11
J8
J5
J13
J12
Operator Power Cable
Strain Relief
Battery wires for
optional second battery.
12 Volt Battery
(included)
Space for optional
second 12 Volt battery
(see Accessory Catalog)
1
ON
234567
1
ON
234
15
BA
T+
SWIT
CH
FUSE
ALARM
SWIT
CH
DU
AL
MODES
SET
LIMIT
LEARN
TRANSMIT
TER
MODES
ON
OFF
ON
OFF
1 2 3 4 5 6 7
1 2 3 4
BA
T–
800-543-GA
TE
www
.gtoinc.com
GT
O
, Inc.
3121 Hartsfield Rd
Ta
lla
h
assee, FL 32303
18 V
A
C
S
OLAR
RELA
Y OUT
~~
-
+
NC
NO
RL
Y-
COM
SLA
VE INPUTS
GRN
WHT
BL
UE
BRN
ORG
RED
BLK
MASTER INPUTS
GRN
WHT
BL
UE
BRN
ORG
RED
BLK
GRN
BLK
RED
RECEIVER
COM
C
OM
CYCLE
CLOSE
SAFETY
EXIT
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
ST
ALL FORCE
MI
N
MAX
J11
J8
J5
J13
J21
J6
J9
J2
J1
J12