23
Setting the Closed Position Limit
TURN CONTROL BOX ON
Your GTO/PRO gate operator has two Limit Settings
1)
OPEN Limit setting:
(Gate in the OPEN POSITION / the limit is FACTORY SET and NOT ADJUSTABLE) The open
limit setting is the fully open position.
2)
CLOSED Limit setting:
(Gate in the CLOSED POSITION) To achieve optimum closed position, you are required
to complete the following FOUR STEPS:
Step 1
Confirm that the power switch is in the ON position and the gate is in the OPEN POSITION.
Step 2
Activate your opener by pressing the entry transmitter
button. Your gate should now be moving from the fully
open position toward the closed position. Prepare to
STOP the gate by pressing the entry transmitter button
again when the gate reaches the desired closed position.
This step may be repeated until desired close position is
achieved. Once the desired CLOSED position has been
achieved, proceed to step 3.
Step 3
With the gate in the desired closed position PRESS &
HOLD the “SET LIMIT" button on the control board for
5 seconds.
Step 4
Press the transmitter button and allow the gate to return
to the fully open position. YOUR GATE’S CLOSED
POSITION LIMIT IS NOW PROGRAMMED.
TESTING YOUR CLOSED LIMIT SETTING:
Press your entry transmitter and allow your gate to close. If the CLOSED position is not correct or needs to be changed, you
will need to CLEAR your CLOSED LIMIT settings and follow Steps 1-4 again.
CLEARING THE PROGRAMMED CLOSED LIMIT SETTING:
If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to the fully opened
position, then press and hold the "SET LIMIT" button for 10 seconds. This will clear the memory for the closed limit
position. Follow Steps 1-4 again.
1
ON
234567
SET
LIMIT
LEARN
TRANSMIT
TER
MODES
ON
OFF
1 2 3 4 5 6 7
Set Limit Button
ST
ALL FORCE
MI
N
MAX
GRN
BLK
RED
RECEIVER
COM
COM
CYCLE
CLOSE
SAFETY
EXIT
OPEN
SHADOW
LOOP
CLOSE
EDGE
OPEN
EDGE
J11
J8
J12