GTO 2000XLS Instruction Manual © 02.07.12
3
2. Check Direction of Gate Swing
The 2000XLS is designed for PULL-TO-OPEN installations.
PUSH-TO-OPEN installations require a Push-To-Open Bracket
[3471H]. Please refer to specific Push-To-Open Installation
Information on page 19.
4. Gate Grounding
• Shorter cable is better, 1 to 2 feet
recommended.
• Bolt ring terminal at end of cable
4 - 6 inches above ground level.
R4196 Kit Includes:
u
Ground Rod Clamp
v
6 AWG Wire (3 feet)
NOTE: No grounding system
absolutely protects against
lightning strikes. If installed
correctly, a grounding system will
help minimize damage to your
gate opener.
E
A
B
C
D
F
A – Level
D – Posts Secured in Concrete
B – Plumb
E – Centerline Mounting
C – Free Swinging
F – Good Working Hinges
Horizontal Cross Member
Vertical Cross Member
Your Property
Your Property
Pull-To-Open
(arm retracts to open)
Push-To-Open
(arm extends to open)
3. Prepare the Gate
• The gate must be plumb, level, and swing freely on its hinges.
• The gate must move throughout its arc without binding or dragging on the ground.
• Wheels must NOT be attached to the gate.
• Gates over 250 lb. should have ball bearing hinges with grease fittings.
• Post must be secured in the ground with concrete (minimizes twist/flex when the operator is
activated).
• Make sure there is a stable area for mounting the gate bracket (this may require the addition of a
horizontal or vertical cross member).
• We recommend you position the operator near the center-line of the gate to keep the gate from
twisting and flexing, and to avoid back-splash from rain.
Metal Gate
Post
6 AWG Wire
8 Foot Ground Rod
5/8” Copper Clad Steel (not included)
- available at local homecenter and hardware stores -
Ground Rod
Clamp