20
GTO 2000XLS Instruction Manual © 02.07.12
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
FIRST Opener
JOG Buttons
SET LIMIT Button
SET LIMIT Light
Step 1: Remove Push-To-Open Jumper
A. Make sure the control box power switch is OFF.
B. Use small pliers to remove the JUMPER for PUSH-TO-
OPEN applications.
C. Turn power switch ON. The control board is now
configured to push the gate open. (Keep the jumper, as it
is necessary if there is ever a need to convert the opener
for Pull-To-Open.)
Step 2: Set the Open Position Limit (Push-to-Open)
The CLOSED limit is when the opener is fully retracted and the
gate is in the closed position. The closed limit setting can only
be adjusted by moving the gate bracket.
To acheive the optimum open position,
you must adjust the OPEN Limit setting:
A. If not already ON slide the ON/OFF
switch on the Control Box to the
ON position and make sure the arm
is in the CLOSED POSITION (fully
retracted).
B. Press and HOLD the FIRST Opener
OPEN button on the control board
and be prepared to RELEASE the
button when the gate reaches the
desired open position/limit. Use the
JOG OPEN and CLOSE buttons to
"fine tune" the gate position if neccessary.
C. NOTE: The opener arm must be extended more than 7 inches to set limits. With the gate in in the
desired open position PRESS and HOLD the SET LIMIT button until the alarm and RED Light come
on. Then release the button.
D. NOTE: When the control box cover is removed the receiver range is reduced to less than 5 feet. Press
the transmitter button once and allow the gate to fully close. The alarm will beep once when the gate
reaches the CLOSED LIMIT. This indicates the LIMITS for the arm are learned and stored in memory.
E. Press the transmitter button and allow the gate to fully open to verify that it stops at the desired
positions. Repeat Steps B – D if correction is needed.
Note: Must have a transmitter that operates the gate. If not, see Personalize Your Transmitter Setting on page 18.
MIN
MAX OFF
REMOVE JUMPER FOR
PUSH TO OPEN OPTION
120
SEC.
STALL FORCE
OPEN < JOG > CLOSE
PWR.
SET
LIMIT
1st OPR.
2nd OPR.
STATUS
AUTO CLOSE
Push-To-Open Jumper