26
GTO 2000XLS Instruction Manual © 02.07.12
Gate and Opener Maintenance:
1. Keep gates properly maintained. Grease hinges. Make sure gates remain level. Replace worn or damaged
hardware. On gates over 250 lbs, grease ball bearing hinges at least 4 times annually (more if in a coastal
area).
2. Service the gate opener regularly (make sure control box is OFF). Apply silicone spray to a soft, dry cloth and
clean the push-pull tube at least once a month.
VOLTAGE READINGS
14 Vac Transformer _____________ 13.0 to 16.0 Vac
10 W Solar panel _______________ 18.0 to 22.0 Vdc
Measure voltage at panel and control box w/ panel disconnected.
12 V Battery ____________________ 12.5 to 13.5 Vdc
Charging circuit ________________ 13.8 to 14.8 Vdc
Measure voltage at battery terminals with battery disconnected.