background image

  LPA 3000XLS/3200XLS Instruction Manual  

15

Connect Operator Power Cables

Step 2 

Loosen sealing nuts on strain relief hubs at 

bottom of control box.  Insert  power cables 

into control box through strain reliefs.  Thread 

approximately 6” to 8” of the power cables into 

the control box and retighten sealing nuts until 

the power cables lock into place.

Sealing Nut

Hub

Lock Nut

Strain Relief

Step 1

Review the Installation Overview illustration below before proceeding.
Cut a slot into the driveway to accommodate 3/4” PVC conduit (not provided).  The buried conduit will 

protect the SECOND operator power cable from automobile tires, lawn mower blades, weed eaters, and 

grazing animals.  Pull the SECOND operator power cable through the conduit, up to the Control Box.

Receiver

PVC  conduit (not included)

to protect SECOND operator 

power cable from lawn mowers

 and weed eaters.

Control Box

Power Cable

from SECOND

Gate Operator

GATES IN THE OPEN POSITION 

WITH OPERATORS INSTALLED

MASTER Gate Operator

Power Cable

from MASTER

Gate Operator

SECOND Gate Operator    

Power Cable from

Second Operator

Power Cable from

Master Operator

Strain Relief

Summary of Contents for 3000XLS

Page 1: ...ith this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value READ ALL INSTRUCTIONS CAREFULLY AND COM...

Page 2: ...stricted Access Vehicular Gate Operator Class IV A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted...

Page 3: ...e Bracket 10 Attach Operator 10 Install the Second Gate Operator 11 Install the Closed Position Stops 11 Mount Battery Box and Control Box 13 Connect Battery 13 Connect Operator Power Cables 15 Connec...

Page 4: ...erators feature adjustable stall force This safety feature makes the gates stop and reverse direction within two seconds when it comes in contact with an obstruction The MIN setting means the gate wil...

Page 5: ...s manual are identified with this warning symbol The symbol identifies conditions that can result in damage to the operator or its components serious injury or death Because GTO automatic gate operato...

Page 6: ...alled and swings freely in both directions Repair or replace all worn or damaged gate hardware prior to installation A freely moving gate will require less force to operate and will enhance the perfor...

Page 7: ...ach the warning signs included to each side of the gate to alert the public of auto matic gate operation It is your responsibility to post warning signs on both sides of your gate If any of these sign...

Page 8: ...ess Systems at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Safety Precautions for Ga...

Page 9: ...B A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage C A wireless contact sen...

Page 10: ...using Conforms to UL STD 325 Certified to CSA STD C22 2 No 247 Maximum Gate 650 lb 294 8 kg 16 ft 4 9 m Voltage 12 Vdc Frequency 0 Hz Power 60 W Class I II Vehicular Swing Gate Operator 3000XLS SERIES...

Page 11: ...nting point to mounting point arm stroke 16 max Minimum gate length is 5 ft Adjustable auto close 3 to 120 seconds and stall force potentiometers Power terminal block accommodates a transformer or sol...

Page 12: ...battery FM123 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor stranded direct burial wire RB509 Do not run m...

Page 13: ...zontal Cross Member Vertical Cross Member Your Property Your Property Pull To Open arm retracts to open Push To Open arm extends to open 3 Prepare the Gates The gate must be plumb level and swing free...

Page 14: ...Cable GTO Transmitter 1 RB741 Master Gate Operator 1 LPA 3000XLS Arm BRACKET BOX HB301 CONTROL BOX AND ELECTRICAL COMPONENTS HARDWARE BAG H301P Control Box 1 Receiver 1 Hairpin Clip 2 3 8 x 2 1 2 Clev...

Page 15: ...gns 2 Second Gate Operator 1 LPA 3200XLS Arm 40 Power Cable BRACKET BOX HB301 HARDWARE BAG H301P Hairpin Clip 2 3 8 x 2 1 2 Clevis Pin 1 1 2 x 2 3 4 Bolt 2 3 8 x 3 Bolt 2 3 8 x 8 Bolt 4 8 Nylon Cable...

Page 16: ...lts Page 11 Surge protection for transformer Page 18 Weatherproof cover for transformer if installed outside Page 18 For push to open applications you must have two 2 PTO Brackets R4388 Drill Bit Dril...

Page 17: ...necessary to use hex head bolts longer than those supplied Round wood posts no smaller than 8 diameter may be notched to create a flat surface for attaching the post bracket Wood posts will require a...

Page 18: ...he position of post bracket holes on the post Step 3 Drill holes through post as marked using a 3 8 drill bit Install the post bracket using the 3 8 x 8 hex head bolts and 3 8 flat washers lock washer...

Page 19: ...est part of the operator arm and the gate When you have achieved the best position for the post pivot bracket in the open position insert the 3 8 x 3 bolt and 3 8 flat washer through the aligned holes...

Page 20: ...ke sure the gate bracket is clamped securely Install Gate Bracket Step 9 Detach the front mount from the gate bracket Check that the gate bracket holes are centered over the scribe line Mark the gate...

Page 21: ...OND Gate Frame MASTER Gate Frame TOP VIEW FRONT VIEW Step 1 Detach the gate operators from the gates and move the gates to their closed position Illustration A Using appropriate hardware for your type...

Page 22: ...plate The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground we recommend setting i...

Page 23: ...he KNOCK OUT in the back of the CONTROL BOX Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX Connecting the Battery Step 3 Slide the battery into position with the terminals t...

Page 24: ...rent locations before permanently mounting the receiver The receiver range can vary from 50 to 100 feet depending upon weather topography and external interference Mount the receiver Ensuring a line o...

Page 25: ...Cut a slot into the driveway to accommodate 3 4 PVC conduit not provided The buried conduit will protect the SECOND operator power cable from automobile tires lawn mower blades weed eaters and grazin...

Page 26: ...GRN terminal the white wire into WHT the blue wire into BLUE brown wire into BRN orange wire into ORG red wire into RED and the black wire into the BLK terminal Tighten the set screws against the end...

Page 27: ...rom an AC power source you will need to use at least 10 watts solar charging power FM122 FM123 to charge the battery Refer to the Solar Panels and Gate Activity Chart on page 2 Step 1 Make sure the co...

Page 28: ...screws against exposed end of wires Step 6 At the transformer strip 1 2 of insulation from the ends of the low voltage wire Twist tightly and attach wires to the transformer terminals Make sure the ex...

Page 29: ...old LEARN MAST LIMIT for 5 seconds or until buzzer beeps to set closed postion B If the second gate reaches closed postion first press and hold LEARN 2ND LIMIT for 5 seconds or until buzzer beeps to s...

Page 30: ...w programmed Control Box Learn Master Limit Button 1 2 3 4 ON DIP STATUS LEARN RMT LEARN MAST LIMIT LEARN 2ND LIMIT S3 S4 S2 SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON...

Page 31: ...to increase the stall force in cold temperatures due to increased resistance from gate hinges Set Auto Close Time The Auto Close Time potentiometer controls the Auto Close feature and determines how...

Page 32: ...close the access cover WARNING No other adjustments should be made inside the transmitter Step 3 Program the new setting into the control board A Press and hold transmitter button B Press and hold th...

Page 33: ...the obstruction warning DIP Switch 3 Push Pull to Open ON Push to open OFF Pull to open factory preset If your gate opens into the property the DIP Switch is set to the OFF position factory setting I...

Page 34: ...this input while at open limit will restart the auto close time if enabled Activation of this input while gate is idle will prevent gate from closing 5 SHADOW LOOP Typically for use with loop detecto...

Page 35: ...ONTROL INPUTS CLOSE EDGE 2 3 4 5 6 7 WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK GRN COM CYCLE COM LOCK PWR AUX RLY POWER INPUT CONTROL OUTPUTS MASTER OPERATOR 2ND OPERATOR CONTROL INPUTS GTO...

Page 36: ...sh to Open Post Pivot Bracket R4388 in the Post Bracket assembly B 4 IMPORTANT While determining the mounting point for the post pivot bracket assembly be sure that the position allows for 2 clearance...

Page 37: ...Box Master Gate Operator Second Gate Operator Step 2 Press the transmitter to activate operator arms The gates will begin to open Gates Opening Control Box Step 3 When either gate reaches OPEN positi...

Page 38: ...tivate operator arms The gates will begin to OPEN Step 6 The gate that was programmed in step 4 will stop on its own Press the transmitter again to stop the other gate when it reaches the desired OPEN...

Page 39: ...Counter 1 beep with 10 seconds off Low Battery Condition Fuses Battery Harness Connections Battery Under Load 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Ar...

Page 40: ...accessory Status clear 5 blinks Close Edge Terminal Shorted Disconnect the edge sensor photo beam or any other accessory wired to this terminal Try the remote If the remote works the problem is the ac...

Page 41: ...ired to send in your original equipment for repair Please refer to Manufactures Limited Warranty for complete details Securely pack the component s authorized for return to the factory Include a copy...

Page 42: ...B741 RB742 RB743 Purchase an additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the U...

Page 43: ...property 100 ft range between transmitter and receiver Easy installation LOCKING SECURITY ACCESSORIES Automatic Gate Lock FM144 FM142 The 1 Accessory For Swing Gate Operators Designed for added securi...

Page 44: ...rge Gate Grounding Kit R4196 The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment from lightning strikes There is no protection or grounding system that can complet...

Reviews: