LPA 3000XLS/3200XLS Instruction Manual
19
Step 1
Power switch is on, gates are in the
OPEN position, operator arms fully
retracted.
Gates in
OPEN
Postion
Control
Box
Master
Gate
Operator
Second
Gate
Operator
Step 2
Press the transmitter to activate operator
arms. The gates will begin to CLOSE.
Gates
Closing
Control
Box
Master
Gate
Operator
Second
Gate
Operator
Control Board Settings
Set Closed Position Limit (for Pull-To-Open Applications)
ON/O
FF
Step 3
When either gate reaches CLOSED
position, press transmitter to stop the
gates.
A. If the master gate reaches closed
postion first - press and hold LEARN
MAST LIMIT for 5 seconds, or until
buzzer beeps to set closed postion.
B. If the second gate reaches closed
postion first - press and hold LEARN
2ND LIMIT for 5 seconds, or until buzzer
beeps to set closed postion.
A
. Master Gate Closed
Control
Box
B.
Second Gate Closed
Learn Master
Limit Button
1 2 3 4
ON
DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE TIME
STALL FORCE
Learn 2ND
Limit Button
Learn Master
Limit Button
1 2 3 4
ON
DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE TIME
STALL FORCE
Learn 2ND
Limit Button
A
B