24
LPA 3000XLS/3200XLS Instruction Manual
Input Connections
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to
these inputs.
• All inputs are connected with respect to COMMON terminal.
• The status LED will blink once when its corresponding input is activated.
1 COM: Circuit common (reference for all
logic input)
• Two (2) terminals to provide extra
common connection point.
2 CYCLE/CLOSE:
(Typically for use with
push button or hard-wired keypad)
• Each activation at this input will cycle
the operation as follows:
OPEN–STOP–CLOSE–STOP–OPEN
3 SAFETY: (Typically for use with photo
beam device, loop detector or other
non-contact sensors)
• Activation of this input while the gate is
closing will cause the gate to stop and
return to the opened position.
• Activation of this input while the gate
is opening has no effect (gate will
continue to open).
• Activation of this input while gate is
idle will prevent gate from closing.
4 EXIT/OPEN: (Typically for use with exit
loop or wand)
• Activation of this input will open the
gate if it’s not already at the open
position.
• Activation of this input while at open limit will restart the auto close time (if enabled).
• Activation of this input while gate is idle will prevent gate from closing.
5 SHADOW LOOP: (Typically for use with loop detector)
• This input is only monitored when the gate is at the fully open position. At any other position,
activation of this input has no effect on gate operation.
• Activation of this input while gate at the fully open position will prevent gate from closing.
6 CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7 OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to stop and reverse direction
for approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.
Connecting Accessories
1
2
3
4
7
5
6
RECEIVER
ALM
GT
O R
CVR.
BLK
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
C
ONTR
OL INPUT
S
CLOSE