23

Step 3

Lay the measured length of low voltage wire in a trench following a path from 
the selected electrical outlet to the control box.  Wires coming up from the 
ground should be run through PVC conduit to protect them from lawn mower 
blades, weed eaters, and grazing animals.  Be sure to bury the wire laid in the 
trench.

Step 4

Feed the low voltage wires upward through the strain relief opening on the 
lower left of the control box.  Pull 6" to 8" of wire into the control box and 
tighten the strain relief screw to secure the wires.

IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE

The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC 

sheathed wire.  This particular gauge enables the transformer to provide an adequate charge through the 

control board to the battery at distances up to 1000 ft.

DO NOT

 use telephone wire or solid core wire.  Unlike multi-stranded wire, these types of wire are 

inadequate for use with your gate operator system.  Telephone wire and solid core wire do not deliver 

enough voltage for your gate operator to function and will cause the system to go into a condition known

as "low voltage lockout."

NEVER 

splice wires together.  Splicing permits corrosion and seriously degrades the wire's ability to 

carry an adequate current.  

Step 5

Strip 

3

/

16

" off the ends of the low voltage wire 

and twist tightly.  Attach these ends to the 

18VAC

 

terminals located on the 

POWER IN

 terminal block 

(

see illustration at right

).   

Be certain not to let the 

exposed wires touch each other!

Insert one transformer wire into an 

18VAC

 terminal.  

Insert the other transformer wire into the remaining

 

18VAC

 terminal.  The transformer wires can be 

connected to the

 18VAC 

terminals regardless of color.

Tighten set screws against exposed end of wires. A 
dab of household petroleum jelly on each terminal will 
help prevent corrosion.

RED
BLACK

RED
BLACK

Low Voltage Wire

from AC Transformer

SWITCH

MASTER INPUTS

GRN

WH
T

BLUE

BRN

ORG

RED

BLK

J5

J13

18 VAC

SOLAR

RELAY OUT

~

~

-

+

NC

NO

RLY-COM

SLAVE INPUTS

GRN

WHT

BLUE

BRN

ORG

RED

BLK

J21

J6

J9

J2

J1

WARNING!  DO NOT PLUG THE TRANSFORMER 
INTO AN OUTLET DURING THIS STEP! THE 
TRANSFORMER MUST ONLY BE PLUGGED INTO 
AN OUTLET DURING STEP 7!!

Low Voltage Wire

from Transformer

or Solar Panel

PVC Pipe

Operator Power Cable

12 V Battery

Strain Relief

1

ON

2 3 4 5 6 7

1

ON

2 3 4

15

18VAC

RECEIVER

BAT+

SWITCH

FUSE

ALARM

SWITCH

DUAL

MODES

SET

LIMIT

LEARN

TRANSMITTER

MODES

ON

OFF

ON

OFF

1  2  3  4  5  6  7

1  2  3  4

BAT–

SOLAR RELAY OUT

SLAVE INPUTS

GRN WHT BLUE

BRN ORG

RED BLK

NC RLY-COM NO

MASTER INPUTS

GRN WHT BLUE

BRN ORG

RED BLK

COM COM

CY

CL

E

CL

OS

E

SA

FE

TY

EX

IT

/

OP

EN

SHADOW LO

OP

CL

OS

E

ED

GE

OP

EN

ED

GE

BLK

GRN

RED

+

~

~

12'

10'

8'

14'

16'

GATE LENGTH

800-543-GATE

www.gtoinc.com

GTO, Inc.

3121 Hartsfield Rd

Tallahassee, FL 32303

Summary of Contents for /PRO SW-300

Page 1: ...eleasing GTO Inc from any and all liability If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this p...

Page 2: ...access locations not servicing the general public in which unauthorized access is prevented via supervision by security personnel The GTO PRO 3000 3200 Gate Operators are intended for use with vehicu...

Page 3: ...page 17 Installation of the Closed Position Stops page 18 Mounting the Control Box page 20 Connecting the Operator Power Cables page 21 Powering the System page 22 Solar Chart page 22 Connecting the T...

Page 4: ...ocks and other access control products These optional accessories see the enclosed GTO PRO Accessory Catalog are available The GTO PRO 3000 3200 Operators feature adjustable obstruction sensing This s...

Page 5: ...and warnings in this manual are identi ed with this warning symbol The symbol identi es conditions that can result in damage to the operator or its components serious injury or death Because GTO auto...

Page 6: ...size of gate its frequency of use and the proper class rating 2 Make sure the dual gate has been properly installed and swings freely in both directions Repair or replace all worn or damaged gate hard...

Page 7: ...3 Devices such as contact sensors safety edges and non contact sensors photo beams provide additional protection against entrapment 4 If push buttons or key switches are installed they should be withi...

Page 8: ...pray to it at least once per month 7 Service the gate and gate operator regularly Grease hinges spray push pull tube with high quality silicon spray and replace the battery every 3 5 years 8 To operat...

Page 9: ...s one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by buildin...

Page 10: ...tic gate operation and are required when installing the GTO PRO 3000 3200 Operators Furthermore a walk through gate must be installed if pedestrian traf c is expected near the vehicular gate We recomm...

Page 11: ...ation and manual operation instruction label 1 installed on control box cover Logo and warning labels 2 installed on each side of operator housing 1 KEEP CLEAR Gate may move at any time 2 Do not allow...

Page 12: ...ket 1 Post Pivot Bracket 1 Customer Support Card 1 Post Bracket 2 Closed Position Stop Plate 1 2 Receiver Mounting Screw 5 E Z GATE OPENER 3 8 Bushings 2 ON OFF Transformer 1 Battery 1 Control Box 1 W...

Page 13: ...Gate Operator 1 w 40 Power Cable Gate Bracket 1 Post Pivot Bracket 1 Post Bracket 2 Closed Position Stop Plate 1 2 Mounting Screw 5 3 8 Bushings 2 Warning Signs 2 1 KEEP CLEAR Gate may move at any ti...

Page 14: ...ntrol box See page 22 Powering the System and the Accessory Catalog for wire and solar charging panels If the gate is more than 1000 away from an AC power source you will need to use at least one GTO...

Page 15: ...RF receiver tuned to 318 MHz Operator length with push pull tube fully retracted is 401 4 mounting point to mounting point Adjustable auto close timer OFF to 120 s and obstruction sensitivity Power te...

Page 16: ...is an example of a pull to open installation on a chain link fence and dual gates Mounting the operators on a masonry column requires special procedures see Column Installation Information on page 39...

Page 17: ...uare should be made of metal instead of wood so that it will remain stable while the operator is moving the gate On round posts of 6 diameter or larger the post pivot bracket may not be necessary for...

Page 18: ...8 Lock Washer Post Bracket Assembly 3 8 Washer NOTE The following steps are intended for pull to open gate installations If you are mounting your operators on a push to open gate e g a gate on a slop...

Page 19: ...lt and readjust the pivot bracket until you can achieve these important clearances With the post pivot bracket in the optimum position for clearance and freedom of movement reattach the operator to th...

Page 20: ...upplied must be used Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots Drill 3 8 holes into the gate cross member as marked Mount gate bracket...

Page 21: ...y Installing the Second Operator Step 12 Install the SLAVE operator on the remaining gate leaf by repeating Step 3 through Step 11 starting on page 14 After you have mounted the SLAVE operator proceed...

Page 22: ...to as the SLAVE gate and gate operator Illustration A Closed Position Stop Plate mounted horizontally on metal post with U bolts SLAVE Gate Frame MASTER Gate Frame TOP VIEW FRONT VIEW Step 1 Attach th...

Page 23: ...You must slide the closed position stop plate toward the ground stop until they touch Illustration C Once you have moved the stop plate to the correct position tighten its hardware completely NOTE Fo...

Page 24: ...rminals on the RIGHT The extra vertical battery slot is for an optional second battery An optional second battery can be used for solar and or high traf c applications if needed Use mounting holes and...

Page 25: ...into place Insert the stripped wires of the power cable into the appropriate terminals on the SLAVE OPERATOR terminal block The green wire should be inserted into the GRN terminal the blue wire into B...

Page 26: ...you will plug the transformer Measure the distance from this outlet to the control box following the path where the wire will be laid After you have measured how much wire is needed cut the wire to th...

Page 27: ...Step 5 Strip 3 16 off the ends of the low voltage wire and twist tightly Attach these ends to the 18VAC terminals located on the POWER IN terminal block see illustration at right Be certain not to le...

Page 28: ...trol box to discourage insects from entering it and damaging the control board Step 6 Strip 1 2 of insulation from the ends of the low voltage wire Attach these stripped ends to the transformer termin...

Page 29: ...Close With the Auto Close switch in the OFF position the gate will remain open until it receives another signal from an activation device such as a transmitter keypad or push button control With the...

Page 30: ...en simultaneously SLAVE gate starts to close 8 seconds before MASTER gate 1 ON 2 3 4 DUAL MODES ON OFF 1 2 3 4 1 ON 2 3 4 DUAL MODES ON OFF 1 2 3 4 1 OFF 2 OFF 1 ON 2 OFF and 3 OFF 1 ON 2 OFF and 3 ON...

Page 31: ...utton on the control board for 5 seconds Step 4 Press the transmitter button and allow the gates to return to the fully open position YOUR FIRST GATE S CLOSED POSITION LIMIT IS NOW PROGRAMMED Step 5 A...

Page 32: ...tton and allow the gates to return to the fully open position BOTH YOUR MASTER AND SLAVE GATE S CLOSED POSITION LIMITS ARE NOW PROGRAMMED TESTING YOUR CLOSED LIMIT SETTING Press your entry transmitter...

Page 33: ...this equipment Such modi cations could void the user s authority to operate the equipment Obstruction Sensitivity Potentiometer ALWAYS KEEP SAFETYAT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING Y...

Page 34: ...ing safety device wiring to the terminal blocks Unplugging the transformer does not turn power to the operator OFF Contact Sensor Input Connection Connect one of the OPEN EDGE contact sensor wires to...

Page 35: ...ion PLEASE NOTE Non contact sensors are not included with the GTO PRO 3000 3200 Wire from Non Contact Sensor photo beam STALL FORCE M I N M A X GRN BLK RED RECEIVER COM COM CYCLE CLOSE SAFETY EXIT OPE...

Page 36: ...to the COMMON COM terminal and the other to the CYCLE CLOSE terminal on the GTO PRO 3000 3200 control board Each activation of the accessory will cause the gate to cycle as follows OPEN STOP CLOSE ST...

Page 37: ...e gates are in the closed position 3 8 x 2 Bolt 3 8 Nut Push To Open Bracket optional accessory Post Bracket Post Bracket 3 8 Lock Washer Post Bracket Assembly 3 8 Washer Step 2 After verifying that y...

Page 38: ...in the closed position 2 OPEN Limit setting Gates in the OPEN POSITION To achieve optimum open position you are required to complete the following SEVEN STEPS Step 1 Con rm that the power switch is in...

Page 39: ...transmitter button when the second gate reaches the desired open position This step may be repeated until desired open position is achieved Once the desired OPEN position has been achieved proceed to...

Page 40: ...broken or spliced wires Check the Red STATUS LED on the Control Board IF THE LED IS ON but the unit is not working 1 Check the battery in your transmitter and replace with a fresh one if needed 2 Veri...

Page 41: ...Check the position of the stroke adjustment knob The GTO Inc Technical Service Department is open Monday Friday 8 00 A M 5 00 P M Eastern Time Telephone 800 543 1236 Telephone 850 575 4144 VOLTAGE RA...

Page 42: ...ary the Service Department will assign a Return Goods Authorization RGA number to you 4 Securely pack the component s authorized for return to the factory Write the RGA number issued to you on the out...

Page 43: ...is recommended that you place a steel plate between the operator mounting brackets and masonry surface for additional strength B If a push to open installation is impossible due to traf c hazards terr...

Page 44: ...t battery included Digital Keypad F300 The specially designed digital keypad can be easily installed as a wireless or wired keypad It can be programmed to use up to fteen different personal identi cat...

Page 45: ...battery included HEDDOLF UNIVERSAL RECEIVER MODEL 294 Accessories con t The contents of all material available on this installation manual are copyrighted by GTO Inc GTO unless otherwise indicated Al...

Reviews: