25
1
ON
2 3 4 5 6 7
ON
OFF
1 2 3 4 5 6 7
DIP#6 DIP#7 Delay Time for Auto-Close
ON
ON
15 seconds
ON
OFF
30 seconds
OFF
ON
60 seconds
OFF* OFF* 120 seconds (factory preset)
DIP#5
ON
D1 mode, constant pressure to operate gate.
OFF* B2 mode, momentary contact to operate gate.
DIP#4
ON
Push-to-open operation.
OFF* Pull-to-open operation.
DIP#3
ON
Auto-close enabled.
OFF* Auto-close disabled.
DIP#2
ON*
Buzzer warning enabled.
OFF
Buzzer warning disabled
DIP#1
ON*
Soft start enabled.
OFF
Soft start disabled.
* Factory Preset.
CONTROL BOARD SETTINGS
DIP Switches
Main DIP Switch Settings (MODES)
DIP Switch #1 - Soft Start/Stop
The Soft Start/Stop feature slowly starts
the gate as it begins to open and slows the
gate as it comes to the closed position. This
saves wear and tear on the gate and gate
operator system.
DIP Switch #2 - Warning Buzzer
The Warning Buzzer alerts you when the
gate operator is beginning to either open
or close the gate. It sounds for the first 2
seconds in each direction. It also sounds a
warning when the gate obstructs two times
in one cycle. Switching this to OFF only
disables the open and close warning not the
obstruction warning.
DIP Switch #3 - Auto-Close
With the Auto-Close switch in the OFF
position the gate will remain open until it
receives another signal from an activation
device such as a transmitter, keypad, or
push button control. With the Auto-Close
switch in the ON position the gate operator
will automatically close the gate, if the gate
is in it's open limit position. The time the
gate will remain open is determined using
DIP Switches #6 and #7.
DIP Switch #4 - Push/Pull-to-Open
If your gate opens into the property the
DIP Switch is set to OFF (factory). If your
gate opens out from the property the DIP
Switch must be set to the ON position.
NOTE: if you have a Push-to-Open gate
application you will need a Push-to-Open
bracket (see Push-to-Open Instructions on
page 30).
DIP Switch #5 - B2/D1 Mode
This DIP Switch must remain in the OFF
position unless the gate operator is going
to be used by a guard or gate attendant,
who can only open the gate when constant
pressure is applied to a push button control
device.
DIP Switches #6 and #7
The combination of these two switches
determines the amount of time the gate will
remain open when DIP Switch #3 is set in
the ON position.
IMPORTANT CONTROL BOARD SETTINGS:
CONTROL BOARD DIP SWITCH #1 is factory
preset in the ON position and MUST remain in the
ON position. Changing this setting can damage
your gate, gate opener and
possibly void your warranty!